Background: Transnasal evaporative cooling has sufficient heat transfer capacity for effective intra-arrest cooling and improves survival in swine. The aim of this study was to determine the safety, feasibility, and cooling efficacy of prehospital transnasal cooling in humans and to explore its effects on neurologically intact survival to hospital discharge. Methods and Results: Witnessed cardiac arrest patients with a treatment interval ≤20 minutes were randomized to intra-arrest cooling with a RhinoChill device (treatment group, n=96) versus standard care (control group, n=104). The final analysis included 93 versus 101 patients, respectively. Both groups were cooled after hospital arrival. The patients had similar demographics, initial rhythms, rates of bystander cardiopulmonary resuscitation, and intervals to cardiopulmonary resuscitation and arrival of advanced life support personnel. Eighteen device-related adverse events (1 periorbital emphysema, 3 epistaxis, 1 perioral bleed, and 13 nasal discolorations) were reported. Time to target temperature of 34°C was shorter in the treatment group for both tympanic (102 versus 282 minutes, P=0.03) and core (155 versus 284 minutes, P=0.13) temperature. There were no significant differences in rates of return of spontaneous circulation between the groups (38% in treated subjects versus 43% in control subjects, P=0.48), in overall survival of those admitted alive (44% versus 31%, respectively, P=0.26), or in neurologically intact survival to discharge (Pittsburgh cerebral performance category scale 1 to 2, 34% versus 21%, P=0.21), although the study was not adequately powered to detect changes in these outcomes. Conclusions-: Prehospital intra-arrest transnasal cooling is safe and feasible and is associated with a significant improvement in the time intervals required to cool patients.

Intra-arrest transnasal evaporative cooling : a randomized, prehospital, multicenter study (PRINCE : Pre-ROSC IntraNasal cooling effectiveness) / M. Castrén, P. Nordberg, L. Svensson, F. Taccone, J. Vincent, D. Desruelles, F. Eichwede, P. Mols, T. Schwab, M. Vergnion, C. Storm, A. Pesenti, J. Pachl, F. Guérisse, T. Elste, M. Roessler, H. Fritz, P. Durnez, H. Busch, B. Inderbitzen, D. Barbut. - In: CIRCULATION. - ISSN 0009-7322. - 122:7(2010), pp. 729-736. [10.1161/CIRCULATIONAHA.109.931691]

Intra-arrest transnasal evaporative cooling : a randomized, prehospital, multicenter study (PRINCE : Pre-ROSC IntraNasal cooling effectiveness)

A. Pesenti;
2010

Abstract

Background: Transnasal evaporative cooling has sufficient heat transfer capacity for effective intra-arrest cooling and improves survival in swine. The aim of this study was to determine the safety, feasibility, and cooling efficacy of prehospital transnasal cooling in humans and to explore its effects on neurologically intact survival to hospital discharge. Methods and Results: Witnessed cardiac arrest patients with a treatment interval ≤20 minutes were randomized to intra-arrest cooling with a RhinoChill device (treatment group, n=96) versus standard care (control group, n=104). The final analysis included 93 versus 101 patients, respectively. Both groups were cooled after hospital arrival. The patients had similar demographics, initial rhythms, rates of bystander cardiopulmonary resuscitation, and intervals to cardiopulmonary resuscitation and arrival of advanced life support personnel. Eighteen device-related adverse events (1 periorbital emphysema, 3 epistaxis, 1 perioral bleed, and 13 nasal discolorations) were reported. Time to target temperature of 34°C was shorter in the treatment group for both tympanic (102 versus 282 minutes, P=0.03) and core (155 versus 284 minutes, P=0.13) temperature. There were no significant differences in rates of return of spontaneous circulation between the groups (38% in treated subjects versus 43% in control subjects, P=0.48), in overall survival of those admitted alive (44% versus 31%, respectively, P=0.26), or in neurologically intact survival to discharge (Pittsburgh cerebral performance category scale 1 to 2, 34% versus 21%, P=0.21), although the study was not adequately powered to detect changes in these outcomes. Conclusions-: Prehospital intra-arrest transnasal cooling is safe and feasible and is associated with a significant improvement in the time intervals required to cool patients.
emergency medical services; heart arrest; hypothermia, induced; prehospital emergency care; Administration, Intranasal; Aged; Body Temperature; Cold Temperature; Emergency Medical Services; Female; Heart Arrest; Humans; Hypothermia, Induced; Male; Middle Aged; Prospective Studies; Time Factors; Physiology (medical); Cardiology and Cardiovascular Medicine
Settore MED/41 - Anestesiologia
2010
Article (author)
File in questo prodotto:
File Dimensione Formato  
218_circulation_2010.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 846.09 kB
Formato Adobe PDF
846.09 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/428526
Citazioni
  • ???jsp.display-item.citation.pmc??? 83
  • Scopus 318
  • ???jsp.display-item.citation.isi??? 297
social impact