Background: Immunotoxicological studies in humans are usually carried out via the determination of some selected immune parameters in subjects occupationally and/or environmentally exposed to immunotoxic substance. One of the most often measured parameters is the determination of lymphocyte subsets, which needs to be carried out in a very short time (a few hours) after blood collection. This is the major problem limiting the determination of lymphocyte subpopulations in field studies, where samples are usually collected directly at the workplace, and very often at the end of the workshift. Unfortunately, these collection modalities significantly prolong the time between collection and analysis. The problem is more evident in multicentric studies, where a further problem is represented by the time needed to send samples to the laboratory. Objective: Since an immune evaluation was planned, including the determination of lymphocyte subpopulations CD4 (T-helper), CD8 (T-suppressor cytotoxic) and CD16/CD56 (natural killer) in the project Assessing health effects in man from exposure to low doses of inorganic mercury in environmental and occupational settings", a method was developed for performing cytofluorimetric analysis in "field studies". Methods: The method is based on commercially-available kits, and involves in loco treatment. Wole blood is labeled with monoclonal antibodies, and fixed samples immediately after collection. After the treatment, the samples are ready for flow cytometric analysis, which may be performed after a two-day period from sample collection. Results and Conclusion: The method described is adequate for immunotoxicy testing in field studies because it prolongs the maximum latency time from collection and cytofluorimetric analysis up to 48 hours. A second interesting characteristic of the method is the possibility of using whole blood, without any need of either complex manipulations or particular equipment.

Adattamento del TriTEST TM per la raccolta di campioni ematici in studi multicentrici afferenti ad uno stesso laboratorio / T. Mammone, S. Birindelli, D. Guarneri, A. Messa, N. Schiavulli, A. Carrus, A. Colombi, L. Soleo, C. Colosio, M. Maroni. - In: LA MEDICINA DEL LAVORO. - ISSN 0025-7818. - 93:3(2002), pp. 233-237.

Adattamento del TriTEST TM per la raccolta di campioni ematici in studi multicentrici afferenti ad uno stesso laboratorio

S. Birindelli
Secondo
;
D. Guarneri;A. Messa;A. Colombi;C. Colosio
Penultimo
;
M. Maroni
Ultimo
2002

Abstract

Background: Immunotoxicological studies in humans are usually carried out via the determination of some selected immune parameters in subjects occupationally and/or environmentally exposed to immunotoxic substance. One of the most often measured parameters is the determination of lymphocyte subsets, which needs to be carried out in a very short time (a few hours) after blood collection. This is the major problem limiting the determination of lymphocyte subpopulations in field studies, where samples are usually collected directly at the workplace, and very often at the end of the workshift. Unfortunately, these collection modalities significantly prolong the time between collection and analysis. The problem is more evident in multicentric studies, where a further problem is represented by the time needed to send samples to the laboratory. Objective: Since an immune evaluation was planned, including the determination of lymphocyte subpopulations CD4 (T-helper), CD8 (T-suppressor cytotoxic) and CD16/CD56 (natural killer) in the project Assessing health effects in man from exposure to low doses of inorganic mercury in environmental and occupational settings", a method was developed for performing cytofluorimetric analysis in "field studies". Methods: The method is based on commercially-available kits, and involves in loco treatment. Wole blood is labeled with monoclonal antibodies, and fixed samples immediately after collection. After the treatment, the samples are ready for flow cytometric analysis, which may be performed after a two-day period from sample collection. Results and Conclusion: The method described is adequate for immunotoxicy testing in field studies because it prolongs the maximum latency time from collection and cytofluorimetric analysis up to 48 hours. A second interesting characteristic of the method is the possibility of using whole blood, without any need of either complex manipulations or particular equipment.
Flow cytometer; Immunotoxicology; Lymphocyte subpopulations; Natural killer; T-helper; T-suppressor citotossic; Public Health, Environmental and Occupational Health
Settore MED/44 - Medicina del Lavoro
2002
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/427586
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact