Study objective: We aim to prospectively validate the diagnostic accuracy of the recently developed 0-h/1-h algorithm, using high-sensitivity cardiac troponin T (hs-cTnT) for the early rule-out and rule-in of acute myocardial infarction. Methods: We enrolled patients presenting with suspected acute myocardial infarction and recent (<6 hours) onset of symptoms to the emergency department in a global multicenter diagnostic study. Hs-cTnT (Roche Diagnostics) and sensitive cardiac troponin I (Siemens Healthcare) were measured at presentation and after 1 hour, 2 hours, and 4 to 14 hours in a central laboratory. Patient triage according to the predefined hs-cTnT 0-hour/1-hour algorithm (hs-cTnT below 12 ng/L and D1 hour below 3 ng/L to rule out; hs-cTnT at least 52 ng/L or D1 hour at least 5 ng/L to rule in; remaining patients to the “observational zone”) was compared against a centrally adjudicated final diagnosis by 2 independent cardiologists (reference standard). The final diagnosis was based on all available information, including coronary angiography and echocardiography results, follow-up data, and serial measurements of sensitive cardiac troponin I, whereas adjudicators remained blinded to hs-cTnT. Results: Among 1,282 patients enrolled, acute myocardial infarction was the final diagnosis for 213 (16.6%) patients. Applying the hs-cTnT 0-hour/1-hour algorithm, 813 (63.4%) patients were classified as rule out, 184 (14.4%) were classified as rule in, and 285 (22.2%) were triaged to the observational zone. This resulted in a negative predictive value and sensitivity for acute myocardial infarction of 99.1% (95% confidence interval [CI] 98.2% to 99.7%) and 96.7% (95% CI 93.4% to 98.7%) in the rule-out zone (7 patients with false-negative results), a positive predictive value and specificity for acute myocardial infarction of 77.2% (95% CI 70.4% to 83.0%) and 96.1% (95% CI 94.7% to 97.2%) in the rule-in zone, and a prevalence of acute myocardial infarction of 22.5% in the observational zone. Conclusion: The hs-cTnT 0-hour/1-hour algorithm performs well for early rule-out and rule-in of acute myocardial infarction. [Ann Emerg Med. 2016;68:76-87.]

Multicenter evaluation of a 0-hour/1-hour algorithm in the diagnosis of myocardial infarction with high-sensitivity cardiac troponin T / C. Mueller, E. Giannitsis, M. Christ, J. Ordóñez Llanos, C. Defilippi, J. Mccord, R. Body, M. Panteghini, T. Jernberg, M. Plebani, F. Verschuren, J. French, R. Christenson, S. Weiser, G. Bendig, P. Dilba, B. Lindahl. - In: ANNALS OF EMERGENCY MEDICINE. - ISSN 0196-0644. - 68:1(2016 Jul), pp. 76-87. [10.1016/j.annemergmed.2015.11.013]

Multicenter evaluation of a 0-hour/1-hour algorithm in the diagnosis of myocardial infarction with high-sensitivity cardiac troponin T

M. Panteghini;
2016

Abstract

Study objective: We aim to prospectively validate the diagnostic accuracy of the recently developed 0-h/1-h algorithm, using high-sensitivity cardiac troponin T (hs-cTnT) for the early rule-out and rule-in of acute myocardial infarction. Methods: We enrolled patients presenting with suspected acute myocardial infarction and recent (<6 hours) onset of symptoms to the emergency department in a global multicenter diagnostic study. Hs-cTnT (Roche Diagnostics) and sensitive cardiac troponin I (Siemens Healthcare) were measured at presentation and after 1 hour, 2 hours, and 4 to 14 hours in a central laboratory. Patient triage according to the predefined hs-cTnT 0-hour/1-hour algorithm (hs-cTnT below 12 ng/L and D1 hour below 3 ng/L to rule out; hs-cTnT at least 52 ng/L or D1 hour at least 5 ng/L to rule in; remaining patients to the “observational zone”) was compared against a centrally adjudicated final diagnosis by 2 independent cardiologists (reference standard). The final diagnosis was based on all available information, including coronary angiography and echocardiography results, follow-up data, and serial measurements of sensitive cardiac troponin I, whereas adjudicators remained blinded to hs-cTnT. Results: Among 1,282 patients enrolled, acute myocardial infarction was the final diagnosis for 213 (16.6%) patients. Applying the hs-cTnT 0-hour/1-hour algorithm, 813 (63.4%) patients were classified as rule out, 184 (14.4%) were classified as rule in, and 285 (22.2%) were triaged to the observational zone. This resulted in a negative predictive value and sensitivity for acute myocardial infarction of 99.1% (95% confidence interval [CI] 98.2% to 99.7%) and 96.7% (95% CI 93.4% to 98.7%) in the rule-out zone (7 patients with false-negative results), a positive predictive value and specificity for acute myocardial infarction of 77.2% (95% CI 70.4% to 83.0%) and 96.1% (95% CI 94.7% to 97.2%) in the rule-in zone, and a prevalence of acute myocardial infarction of 22.5% in the observational zone. Conclusion: The hs-cTnT 0-hour/1-hour algorithm performs well for early rule-out and rule-in of acute myocardial infarction. [Ann Emerg Med. 2016;68:76-87.]
English
Settore BIO/12 - Biochimica Clinica e Biologia Molecolare Clinica
Articolo
Esperti anonimi
Pubblicazione scientifica
lug-2016
Mosby
68
1
76
87
12
Pubblicato
Periodico con rilevanza internazionale
Aderisco
info:eu-repo/semantics/article
Multicenter evaluation of a 0-hour/1-hour algorithm in the diagnosis of myocardial infarction with high-sensitivity cardiac troponin T / C. Mueller, E. Giannitsis, M. Christ, J. Ordóñez Llanos, C. Defilippi, J. Mccord, R. Body, M. Panteghini, T. Jernberg, M. Plebani, F. Verschuren, J. French, R. Christenson, S. Weiser, G. Bendig, P. Dilba, B. Lindahl. - In: ANNALS OF EMERGENCY MEDICINE. - ISSN 0196-0644. - 68:1(2016 Jul), pp. 76-87. [10.1016/j.annemergmed.2015.11.013]
open
Prodotti della ricerca::01 - Articolo su periodico
17
262
Article (author)
no
C. Mueller, E. Giannitsis, M. Christ, J. Ordóñez Llanos, C. Defilippi, J. Mccord, R. Body, M. Panteghini, T. Jernberg, M. Plebani, F. Verschuren, J. French, R. Christenson, S. Weiser, G. Bendig, P. Dilba, B. Lindahl
File in questo prodotto:
File Dimensione Formato  
TRAPID.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 1.08 MB
Formato Adobe PDF
1.08 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/420447
Citazioni
  • ???jsp.display-item.citation.pmc??? 59
  • Scopus 290
  • ???jsp.display-item.citation.isi??? 256
social impact