To study hematotoxicity of compounds on the myeloid cell compartment, the authors describe a standard procedure developed as a workable good laboratory practices–compliant protocol to determine the in vitro myelotoxic effect of drugs and chemicals. Specific protocols are presented to prepare human and murine myeloid progenitors (CFU-GM) for testing in a validated CFU-GM assay. Details are given for performing a screening test when toxicity data are not available and for passing on to an accurate inhibitory concentration–determination phase. To quantify the potential hematotoxicity of xenobiotics from their direct adverse effects on CFU-GM, the unit describes how to manage the results by means of an algorithm able to predict the acute xenobiotic exposure levels that cause maximum tolerated decreases (MTD) in absolute neutrophil count (ANC). A protocol describes a miniaturized application of the procedure in 96-well plates for high-throughput screening of compounds or for testing compounds that are available in very small quantities.

CFU-GM assay for evaluation of drug myelotoxic activity / A. Pessina, A. Bonomi - In: Current protocols in toxicologyNew York : John Wiley & Sons, 2007 Nov. - ISBN 0471241067. - pp. 20.2.1-20.2.18 [10.1002/0471140856.tx2002s34]

CFU-GM assay for evaluation of drug myelotoxic activity

A. Pessina
Primo
;
A. Bonomi
Ultimo
2007

Abstract

To study hematotoxicity of compounds on the myeloid cell compartment, the authors describe a standard procedure developed as a workable good laboratory practices–compliant protocol to determine the in vitro myelotoxic effect of drugs and chemicals. Specific protocols are presented to prepare human and murine myeloid progenitors (CFU-GM) for testing in a validated CFU-GM assay. Details are given for performing a screening test when toxicity data are not available and for passing on to an accurate inhibitory concentration–determination phase. To quantify the potential hematotoxicity of xenobiotics from their direct adverse effects on CFU-GM, the unit describes how to manage the results by means of an algorithm able to predict the acute xenobiotic exposure levels that cause maximum tolerated decreases (MTD) in absolute neutrophil count (ANC). A protocol describes a miniaturized application of the procedure in 96-well plates for high-throughput screening of compounds or for testing compounds that are available in very small quantities.
Settore MED/07 - Microbiologia e Microbiologia Clinica
nov-2007
Book Part (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/41596
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 6
  • ???jsp.display-item.citation.isi??? ND
social impact