Using an innovative time-varying front-end electronics in conjunction with a bulky coaxial high-purity germanium detector, we were able to extend the range of the radionuclide spectra well beyond the analog to digital converter (ADC) saturation point. The electronics automatically conditions the signal for digital-filtering optimization if it is in the ADC voltage range and for time-over-threshold analysis if it exceeds the ADC range. A high spectroscopic resolution has been achieved in both operation ranges. An unprecedented wide energy range from 5 keV to 150 MeV of equivalent energy, or 90 dB, has been obtained using a single acquisition chain, while maintaining a high-energy resolution in the whole spectrum. For example, with an ADC range of 3 MeV a resolution has been obtained of 1.3/2.2 keV full width at half maximum on the 122/1332 keV gamma-ray lines of Co-57 and Co-60, and of <0.4% in the time-over-threshold region, or for energy deposits beyond 3 MeV. (C) 2008 American Institute of Physics.

Extending the dynamic range of nuclear pulse spectrometers / A. Pullia, F. Zocca, G. Pascovici, D. Bazzacco. - In: REVIEW OF SCIENTIFIC INSTRUMENTS. - ISSN 0034-6748. - 79:3(2008 Mar 01), pp. 036105.036105.1-036105.036105.3.

Extending the dynamic range of nuclear pulse spectrometers

A. Pullia
Primo
;
F. Zocca
Secondo
;
2008

Abstract

Using an innovative time-varying front-end electronics in conjunction with a bulky coaxial high-purity germanium detector, we were able to extend the range of the radionuclide spectra well beyond the analog to digital converter (ADC) saturation point. The electronics automatically conditions the signal for digital-filtering optimization if it is in the ADC voltage range and for time-over-threshold analysis if it exceeds the ADC range. A high spectroscopic resolution has been achieved in both operation ranges. An unprecedented wide energy range from 5 keV to 150 MeV of equivalent energy, or 90 dB, has been obtained using a single acquisition chain, while maintaining a high-energy resolution in the whole spectrum. For example, with an ADC range of 3 MeV a resolution has been obtained of 1.3/2.2 keV full width at half maximum on the 122/1332 keV gamma-ray lines of Co-57 and Co-60, and of <0.4% in the time-over-threshold region, or for energy deposits beyond 3 MeV. (C) 2008 American Institute of Physics.
Preamplifier ; dynamic range ; gamma ray spectroscopy
Settore ING-INF/01 - Elettronica
1-mar-2008
Article (author)
File in questo prodotto:
File Dimensione Formato  
Extending the dynamic range of nuclear pulse spectrometers.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 459.21 kB
Formato Adobe PDF
459.21 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/41267
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 17
  • ???jsp.display-item.citation.isi??? 17
social impact