The total selenium content in white, black, red rice and white rice hull samples, grown in Northern Italy cultivars, has been determined using the differential pulse cathodic stripping voltammetry (DPCSV) on the hanging drop mercury electrode (HDME), in the presence of Cu(II). The digestion was performed in open vessel through a combination of wet acid/dry ashing with Mg(II) salts. The calibration curve was linear in the concentration range 0.15â 8 ppb, the detection limit was estimated to be 0.07 ppb, and the recovery was in the range 85â 102%. Reproducibility was from 1.9% to 9.0% (RSD, n = 4). Rice samples were analyzed by the standard addition method and the results were compared with those obtained by a spectroscopic technique (HG-ICP-AES). The proposed procedure, sensitive, inexpensive, easy-to-handle and precise can be successfully applied for the determination of selenium in nutritional products. The resulting selenium contents in different Italian rice varieties were: 20.1 ± 1.8 ppb (white), 53.0 ± 1.0 ppb (red), 26.7 ± 1.3 ppb (black), 45.3 ± 4.1 ppb (white rice hull)

Determination of selenium in Italian rices by differential pulse cathodic stripping voltammetry / M. Panigati, L. Falciola, P. Mussini, G. Beretta, R. Maffei Facino. - In: FOOD CHEMISTRY. - ISSN 0308-8146. - 105:3(2007), pp. 1091-1098.

Determination of selenium in Italian rices by differential pulse cathodic stripping voltammetry

M. Panigati
Primo
;
L. Falciola
Secondo
;
P. Mussini;G. Beretta
Penultimo
;
R. Maffei Facino
Ultimo
2007

Abstract

The total selenium content in white, black, red rice and white rice hull samples, grown in Northern Italy cultivars, has been determined using the differential pulse cathodic stripping voltammetry (DPCSV) on the hanging drop mercury electrode (HDME), in the presence of Cu(II). The digestion was performed in open vessel through a combination of wet acid/dry ashing with Mg(II) salts. The calibration curve was linear in the concentration range 0.15â 8 ppb, the detection limit was estimated to be 0.07 ppb, and the recovery was in the range 85â 102%. Reproducibility was from 1.9% to 9.0% (RSD, n = 4). Rice samples were analyzed by the standard addition method and the results were compared with those obtained by a spectroscopic technique (HG-ICP-AES). The proposed procedure, sensitive, inexpensive, easy-to-handle and precise can be successfully applied for the determination of selenium in nutritional products. The resulting selenium contents in different Italian rice varieties were: 20.1 ± 1.8 ppb (white), 53.0 ± 1.0 ppb (red), 26.7 ± 1.3 ppb (black), 45.3 ± 4.1 ppb (white rice hull)
Selenium ; DPCSV ; Copper(II) ; White and coloured rices ; White rice hull
Settore CHIM/01 - Chimica Analitica
Settore CHIM/08 - Chimica Farmaceutica
2007
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/40059
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 32
  • ???jsp.display-item.citation.isi??? 30
  • OpenAlex ND
social impact