The construction of the ATLAS electromagnetic liquid argon calorimeter modules is completed and all the modules are assembled and inserted in the cryostats. During the production period four barrel and three endcap modules were exposed to test beams in order to assess their performance, ascertain the production quality and reproducibility, and to scrutinize the complete energy reconstruction chain from the readout and calibration electronics to the signal and energy reconstruction. It was also possible to check the full Monte Carlo simulation of the calorimeter. The analysis of the uniformity, resolution and extraction of constant term is presented. Typical non-uniformities of 0.5% and typical global constant terms of 0.6% are measured for the barrel and end-cap modules.

Response uniformity of the ATLAS liquid argon electromagnetic calorimeter / J. Colas, L. Di Ciaccio, M. Gouanere, R. Lafaye, S. Laplace, P. Perrodo, H. Przysiezniak, G. Sauvage, I. Wingerter-Seez, R. Zitoun, F. Lanni, L. Lu, H. Ma, S. Rajagopalan, H. Takai, A. Belymam, D. Benchekroun, M. Hakimi, A. Hoummada, Y. Gao, R. Stroynowski, M. Aleksa, T. Carli, P. Fassnacht, F. Gianotti, L. Hervas, W. Lampl, J. Collot, J.Y. Hostachy, F. Ledroit-Guillon, F. Malek, P. Martin, S. Viret, M. Leltchouk, J.A. Parsons, S. Simion, F. Barreiro, J. Del Peso, L. Labarga, C. Oliver, S. Rodier, F. Djama, F. Hubaut, E. Monnier, P. Pralavorio, C. Serfon, S. Tisserant, D. Banfi, L. Carminati, D. Cavalli, G. Costa, M. Delmastro, M. Fanti, L. Mandelli, M. Mazzanti, G.F. Tartarelli, K. Kotov, A. Maslennikov, G. Pospelov, Y. Tikhonov, C. Bourdarios, L. Fayard, D. Fournier, L. Iconomidou-Fayard, G. Parrour, P. Puzo, D. Rousseau, L. Serin, D. Zerwas, B. Dekhissi, J. Derkaoui, A. El Kharrim, F. Maaroufi, W. Cleland, D. Lacour, B. Laforge, I. Nikolic-Audit, P. Schwemling, H. Ghazlane, R. Cherkaoui El Moursli, A. Idrissi Fakhr-Eddine, M. Boonekamp, N. Kerschen, B. Mansoulie, P. Meyer, J. Schwindling, B. Lund-Jensen. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 582:2(2007 Sep), pp. 429-455. [10.1016/j.nima.2007.08.157]

Response uniformity of the ATLAS liquid argon electromagnetic calorimeter

D. Banfi;L. Carminati;M. Fanti;L. Mandelli;
2007

Abstract

The construction of the ATLAS electromagnetic liquid argon calorimeter modules is completed and all the modules are assembled and inserted in the cryostats. During the production period four barrel and three endcap modules were exposed to test beams in order to assess their performance, ascertain the production quality and reproducibility, and to scrutinize the complete energy reconstruction chain from the readout and calibration electronics to the signal and energy reconstruction. It was also possible to check the full Monte Carlo simulation of the calorimeter. The analysis of the uniformity, resolution and extraction of constant term is presented. Typical non-uniformities of 0.5% and typical global constant terms of 0.6% are measured for the barrel and end-cap modules.
Electronics, readout ; calorimeter, electromagnetic ; calorimeter, liquid argon ; time, calibration ; ATLAS ; p p, colliding beam detector ; calibration, quality ; position dependence ; CERN LHC Coll
Settore FIS/01 - Fisica Sperimentale
Settore FIS/04 - Fisica Nucleare e Subnucleare
set-2007
http://arxiv.org/pdf/0709.1094
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/39657
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 32
  • ???jsp.display-item.citation.isi??? 33
social impact