Background: To present the technique and dose distribution of intraoperative radiotherapy (IORT) for prostate cancer. Patients and Methods: Pelvic lymphadenectomy, prostate IORT and radical retropubic prostatectomy was performed in 11 prostate cancer patients. Prostate thickness and rectum depth were measured with intraoperative ultrasound. IORT was delivered by a mobile linear accelerator in the operating room (electron beam, 12 Gy at 90% isodose). Results: The mean preoperative probability of organ-confined disease was 10% (Memorial Sloan Kettering Cancer Center nomograms). Mean prostate thickness, width and length were 3.4 cm, 4.6 and 4.9 cm, respectively. Mean rectum depth was 3.3 cm. Mean doses to the posterior prostate capsule, 5-mm lateral prostate margins and at the subsequent uretheral stump area were 4.6 Gy, 8.7 Gy and 11.3 Gy, respectively. Maximum mean rectal dose was 4.9 Gy. Conclusion: IORT appeared a feasible approach for prostate cancer, showing a satisfactory dose coverage to the prostate bed with relatively low rectal dose. However, high variability in dose distribution calls for further study of patient selection criteria and dosimetry.

Intraoperative radiotherapy for locally advanced prostate cancer : treatment technique and ultrasound-based analysis of dose distribution / R. Orecchia, B.A. Jereczek-Fossa, M. Ciocca, A. Vavassori, R. Cambria, F. Cattani, D. Zerini, D.V. Matei, B. Rocco, F. Verweij, E. Scardino, O. De Cobelli. - In: ANTICANCER RESEARCH. - ISSN 0250-7005. - 27:5B(2007 Sep), pp. 3471-3476.

Intraoperative radiotherapy for locally advanced prostate cancer : treatment technique and ultrasound-based analysis of dose distribution

R. Orecchia
Primo
;
B.A. Jereczek-Fossa
Secondo
;
B. Rocco;O. De Cobelli
Ultimo
2007

Abstract

Background: To present the technique and dose distribution of intraoperative radiotherapy (IORT) for prostate cancer. Patients and Methods: Pelvic lymphadenectomy, prostate IORT and radical retropubic prostatectomy was performed in 11 prostate cancer patients. Prostate thickness and rectum depth were measured with intraoperative ultrasound. IORT was delivered by a mobile linear accelerator in the operating room (electron beam, 12 Gy at 90% isodose). Results: The mean preoperative probability of organ-confined disease was 10% (Memorial Sloan Kettering Cancer Center nomograms). Mean prostate thickness, width and length were 3.4 cm, 4.6 and 4.9 cm, respectively. Mean rectum depth was 3.3 cm. Mean doses to the posterior prostate capsule, 5-mm lateral prostate margins and at the subsequent uretheral stump area were 4.6 Gy, 8.7 Gy and 11.3 Gy, respectively. Maximum mean rectal dose was 4.9 Gy. Conclusion: IORT appeared a feasible approach for prostate cancer, showing a satisfactory dose coverage to the prostate bed with relatively low rectal dose. However, high variability in dose distribution calls for further study of patient selection criteria and dosimetry.
Electron beam; Intraoperative radiotherapy; Prostate cancer; Prostatectomy; Ultrasound-based dosimetry
Settore MED/36 - Diagnostica per Immagini e Radioterapia
Settore MED/24 - Urologia
set-2007
Article (author)
File in questo prodotto:
File Dimensione Formato  
3471.full.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 223.68 kB
Formato Adobe PDF
223.68 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/38167
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 16
social impact