Background: To present the technique and dose distribution of intraoperative radiotherapy (IORT) for prostate cancer. Patients and Methods: Pelvic lymphadenectomy, prostate IORT and radical retropubic prostatectomy was performed in 11 prostate cancer patients. Prostate thickness and rectum depth were measured with intraoperative ultrasound. IORT was delivered by a mobile linear accelerator in the operating room (electron beam, 12 Gy at 90% isodose). Results: The mean preoperative probability of organ-confined disease was 10% (Memorial Sloan Kettering Cancer Center nomograms). Mean prostate thickness, width and length were 3.4 cm, 4.6 and 4.9 cm, respectively. Mean rectum depth was 3.3 cm. Mean doses to the posterior prostate capsule, 5-mm lateral prostate margins and at the subsequent uretheral stump area were 4.6 Gy, 8.7 Gy and 11.3 Gy, respectively. Maximum mean rectal dose was 4.9 Gy. Conclusion: IORT appeared a feasible approach for prostate cancer, showing a satisfactory dose coverage to the prostate bed with relatively low rectal dose. However, high variability in dose distribution calls for further study of patient selection criteria and dosimetry.
Intraoperative radiotherapy for locally advanced prostate cancer : treatment technique and ultrasound-based analysis of dose distribution / R. Orecchia, B.A. Jereczek-Fossa, M. Ciocca, A. Vavassori, R. Cambria, F. Cattani, D. Zerini, D.V. Matei, B. Rocco, F. Verweij, E. Scardino, O. De Cobelli. - In: ANTICANCER RESEARCH. - ISSN 0250-7005. - 27:5B(2007 Sep), pp. 3471-3476.
Intraoperative radiotherapy for locally advanced prostate cancer : treatment technique and ultrasound-based analysis of dose distribution
R. OrecchiaPrimo
;B.A. Jereczek-FossaSecondo
;B. Rocco;O. De CobelliUltimo
2007
Abstract
Background: To present the technique and dose distribution of intraoperative radiotherapy (IORT) for prostate cancer. Patients and Methods: Pelvic lymphadenectomy, prostate IORT and radical retropubic prostatectomy was performed in 11 prostate cancer patients. Prostate thickness and rectum depth were measured with intraoperative ultrasound. IORT was delivered by a mobile linear accelerator in the operating room (electron beam, 12 Gy at 90% isodose). Results: The mean preoperative probability of organ-confined disease was 10% (Memorial Sloan Kettering Cancer Center nomograms). Mean prostate thickness, width and length were 3.4 cm, 4.6 and 4.9 cm, respectively. Mean rectum depth was 3.3 cm. Mean doses to the posterior prostate capsule, 5-mm lateral prostate margins and at the subsequent uretheral stump area were 4.6 Gy, 8.7 Gy and 11.3 Gy, respectively. Maximum mean rectal dose was 4.9 Gy. Conclusion: IORT appeared a feasible approach for prostate cancer, showing a satisfactory dose coverage to the prostate bed with relatively low rectal dose. However, high variability in dose distribution calls for further study of patient selection criteria and dosimetry.File | Dimensione | Formato | |
---|---|---|---|
3471.full.pdf
accesso aperto
Tipologia:
Publisher's version/PDF
Dimensione
223.68 kB
Formato
Adobe PDF
|
223.68 kB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.