Linear sulphonated poly(arylethersulphone) (SPAES) membranes were tested and compared with Nafion, as electrode modifiers for electroanalytical purposes. Different preparation parameters were evaluated: casting solvent, method of drying and storage, polymer ionic moieties counter-ion. In particular, the casting solvent seems to play a key role in the final modified electrode performances. Four solvents characterized by different boiling point and polarity were tested: dimethylformamide (DMF), N,N-dimethylacetamide (DMAc), dimethylsulfoxide (DMSO), N-methylpyrrolidone (NMP). The best electrode, particularly in terms of highest peak currents, was the one prepared using a 1% m/v solution of polymer in NMP, dried at 25 °C in a drying oven. Its performances are explained in terms of a favourable membrane organization enabling a thin layer diffusion and/or a preconcentration mechanism.
Electrodes modified with sulphonated poly(aryl ether sulphone) : effect of casting conditions on their enhanced electroanalytycal performance / L. Falciola, S. Checchia, V. Pifferi, H. Farina, M.A. Ortenzi, V. Sabatini. - In: ELECTROCHIMICA ACTA. - ISSN 0013-4686. - 194(2016 Mar 10), pp. 405-412. [10.1016/j.electacta.2016.02.110]
Electrodes modified with sulphonated poly(aryl ether sulphone) : effect of casting conditions on their enhanced electroanalytycal performance
L. FalciolaPrimo
;S. ChecchiaSecondo
;V. Pifferi
;H. Farina;M.A. OrtenziPenultimo
;V. SabatiniUltimo
2016
Abstract
Linear sulphonated poly(arylethersulphone) (SPAES) membranes were tested and compared with Nafion, as electrode modifiers for electroanalytical purposes. Different preparation parameters were evaluated: casting solvent, method of drying and storage, polymer ionic moieties counter-ion. In particular, the casting solvent seems to play a key role in the final modified electrode performances. Four solvents characterized by different boiling point and polarity were tested: dimethylformamide (DMF), N,N-dimethylacetamide (DMAc), dimethylsulfoxide (DMSO), N-methylpyrrolidone (NMP). The best electrode, particularly in terms of highest peak currents, was the one prepared using a 1% m/v solution of polymer in NMP, dried at 25 °C in a drying oven. Its performances are explained in terms of a favourable membrane organization enabling a thin layer diffusion and/or a preconcentration mechanism.File | Dimensione | Formato | |
---|---|---|---|
EleActa2016.pdf
accesso riservato
Descrizione: Articolo pubblicato
Tipologia:
Publisher's version/PDF
Dimensione
1.37 MB
Formato
Adobe PDF
|
1.37 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.