The V-index is a recently-proposed metric related to repolarization heterogeneity (RH) across the myocardium, a key quantity for the development of arrhythmias. The metric is derived from multi-leads ECG recordings and this paper investigates two of its properties: i) the dependency on the lead system (Frank's orthogonal vs. 12 standard leads); ii) the influence of errors in the location of the T-end position. The first investigation was performed by simulations, using a forward ECG model (ECGSIM). In the lead system of interest, the V-index was computed varying the standard deviation of RH (sv). The results showed that the average bias in the estimate of RH (at σφ = 1 ms) ranged from -20.4±4.0% (sv = 20.6 ms) to -26.3±4.0% (sv = 70.9 ms) for the standard system and from -7.0 ± 4.2% to - 19.0 ± 4.2% for the Frank's one. While the bias diminished, the vulnerability to noise slightly increased. Secondarily, 68 ECGs from the E-OTH-12-0068-010 THEW database were analyzed. To simulate mislocation, the T-end point was consistently moved (±20 ms) around its correct position and the V-index computed. The average differences in the V-index estimates across the population were always smaller than 1%. This is a desirable property, given the discrepancies across methods in locating T-end positions.
Quantification of spatial repolarization heterogeneity: testing the robustness of a new technique / R. Sassi, L.T. Mainardi - In: Computing in Cardiology (CinC), 2012[s.l] : IEEE P, 2012. - ISBN 9781467320764. - pp. 69-72 (( Intervento presentato al 39. convegno CINC tenutosi a Krakow nel 2012.
Quantification of spatial repolarization heterogeneity: testing the robustness of a new technique
R. Sassi
;
2012
Abstract
The V-index is a recently-proposed metric related to repolarization heterogeneity (RH) across the myocardium, a key quantity for the development of arrhythmias. The metric is derived from multi-leads ECG recordings and this paper investigates two of its properties: i) the dependency on the lead system (Frank's orthogonal vs. 12 standard leads); ii) the influence of errors in the location of the T-end position. The first investigation was performed by simulations, using a forward ECG model (ECGSIM). In the lead system of interest, the V-index was computed varying the standard deviation of RH (sv). The results showed that the average bias in the estimate of RH (at σφ = 1 ms) ranged from -20.4±4.0% (sv = 20.6 ms) to -26.3±4.0% (sv = 70.9 ms) for the standard system and from -7.0 ± 4.2% to - 19.0 ± 4.2% for the Frank's one. While the bias diminished, the vulnerability to noise slightly increased. Secondarily, 68 ECGs from the E-OTH-12-0068-010 THEW database were analyzed. To simulate mislocation, the T-end point was consistently moved (±20 ms) around its correct position and the V-index computed. The average differences in the V-index estimates across the population were always smaller than 1%. This is a desirable property, given the discrepancies across methods in locating T-end positions.File | Dimensione | Formato | |
---|---|---|---|
[28]_CinC_2012_69_Krakow.pdf
accesso aperto
Tipologia:
Publisher's version/PDF
Dimensione
205.58 kB
Formato
Adobe PDF
|
205.58 kB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.