Beat-to-beat variability of the QT interval (QTV) has been used as a marker of repolarization lability and sympathetic activation. The aim of this study was to establish ECG sampling rate requirements for reliable QT interval variability measurement. We measured QTV in high resolution simulated (1000 Hz) and real ECG (1600 Hz; in the supine position during rest and during sympathetic activation upon standing), using time and frequency domain metrics as well as measures of symbolic dynamics for complexity assessment. We successively halved the sampling rate and investigated its effect on the QTV metrics. Reduction in sampling rate below 400 Hz and 500 Hz, respectively, resulted in a significant overestimation of QTV variability and also affected complexity measurement of QTV. QTV increased during standing compared to the supine measurement. At 100 Hz, the posture related change in QTV was completely masked by the measurement noise introduced by the low sampling rate. In conclusion, ECG sampling rates of 500 Hz yields a reliable QTV measurement, while sampling rates of 200 Hz and below should be avoided.

Effects of ECG sampling rate on QT interval variability measurement / M. Baumert, M. Schmidt, S. Zaunseder, A. Porta. - In: BIOMEDICAL SIGNAL PROCESSING AND CONTROL. - ISSN 1746-8094. - 25(2016), pp. 159-164.

Effects of ECG sampling rate on QT interval variability measurement

A. Porta
2016

Abstract

Beat-to-beat variability of the QT interval (QTV) has been used as a marker of repolarization lability and sympathetic activation. The aim of this study was to establish ECG sampling rate requirements for reliable QT interval variability measurement. We measured QTV in high resolution simulated (1000 Hz) and real ECG (1600 Hz; in the supine position during rest and during sympathetic activation upon standing), using time and frequency domain metrics as well as measures of symbolic dynamics for complexity assessment. We successively halved the sampling rate and investigated its effect on the QTV metrics. Reduction in sampling rate below 400 Hz and 500 Hz, respectively, resulted in a significant overestimation of QTV variability and also affected complexity measurement of QTV. QTV increased during standing compared to the supine measurement. At 100 Hz, the posture related change in QTV was completely masked by the measurement noise introduced by the low sampling rate. In conclusion, ECG sampling rates of 500 Hz yields a reliable QTV measurement, while sampling rates of 200 Hz and below should be avoided.
ECG; QT interval; Sampling rate
Settore ING-INF/06 - Bioingegneria Elettronica e Informatica
2016
Article (author)
File in questo prodotto:
File Dimensione Formato  
Baumert_BSPC_2016.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 641.63 kB
Formato Adobe PDF
641.63 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/353630
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 18
social impact