The biocompatibility of dental materials is a topic of increasing importance for dentists. We investigated the effects of alloys for ceramic crowns and removable prostheses on the skin and lymphoid organs of rats. We used three groups of Sprague Dawley rats: group I as the control, with groups II and III implanted with different biomaterials into subcutaneous pockets. After sacrifice, the rat skin around the implant and the lymph nodes was studied. The tissues of implanted rats were morphologically different from the control animals as they showed a number of mast cells that increased 7 days after the implant with both alloys. These cells decreased 14 days after the implant with alloy for ceramic crowns whereas they were still high 28 days after the implant with alloy for removable prostheses. The findings suggest that both alloys induced different and time-dependent inflammatory reactions. Our findings have importance in the future rational design of biocompatible implantable and blood-contact biomaterials.

Mast cells and the inflammatory response to different implanted biomaterials / R. Rezzani, L. Rodella, G.M. Tartaglia, C. Paganelli, P. Sapelli, R. Bianchi. - In: ARCHIVES OF HISTOLOGY AND CYTOLOGY. - ISSN 0914-9465. - 67:3(2004 Sep), pp. 211-217.

Mast cells and the inflammatory response to different implanted biomaterials

G.M. Tartaglia;R. Bianchi
Ultimo
2004

Abstract

The biocompatibility of dental materials is a topic of increasing importance for dentists. We investigated the effects of alloys for ceramic crowns and removable prostheses on the skin and lymphoid organs of rats. We used three groups of Sprague Dawley rats: group I as the control, with groups II and III implanted with different biomaterials into subcutaneous pockets. After sacrifice, the rat skin around the implant and the lymph nodes was studied. The tissues of implanted rats were morphologically different from the control animals as they showed a number of mast cells that increased 7 days after the implant with both alloys. These cells decreased 14 days after the implant with alloy for ceramic crowns whereas they were still high 28 days after the implant with alloy for removable prostheses. The findings suggest that both alloys induced different and time-dependent inflammatory reactions. Our findings have importance in the future rational design of biocompatible implantable and blood-contact biomaterials.
set-2004
http://www.jstage.jst.go.jp/article/aohc/67/3/67_211/_article
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/35301
Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 17
social impact