AIMS AND BACKGROUND: This study evaluates 3 different imaging modalities--ultrasound (US), stereoscopic X-ray imaging of implanted markers (Visicoils) (X-ray), and kV cone-beam computed tomography (CBCT)--to assess interfraction and intrafraction localization error during conformal radiation therapy of prostate cancer. METHODS AND STUDY DESIGN: The study population consisted of 186 consecutive prostate cancer patients treated with an image-guided radiotherapy (IGRT) hypofractionated protocol using 3 techniques: 32 with X-ray, 30 with CBCT, and 124 with US. Treatment dose of 70.2 Gy was delivered in 26 fractions with a conformal dynamic arcs technique. Interfraction prostate localization errors were determined for the 3 techniques. Moreover, interfraction and intrafraction prostate motion in terms of translations and rotations, as well as residual errors, were determined with X-ray. RESULTS: The systematic and random components of the prostate localization errors were as follows: (1) with X-ray 3.0 ± 3.4, 2.3 ± 2.7, 1.8 ± 2.3 mm in anterior-posterior (AP), superior-inferior (SI), and left-right (LR) directions and 1.8° ± 1.2°, 2.3° ± 1.5°, 2.7° ± 3.1°, for the yaw, roll, and pitch rotations; (2) with CBCT 3.5 ± 4.2, 3.3 ± 3.3, 2.5 ± 3.1 mm in AP, SI, and LR directions; (3) with US 3.7 ± 4.7, 3.4 ± 4.3, 2.3 ± 3.5 mm in AP, SI, and LR directions. Residual errors with X-ray were less than 1 mm in all directions. Intrafraction prostate motion of less than 0.5 mm in LR and of the order of 1 mm in AP and SI directions was found. This led to a significant reduction of the margins, potentially important for dose escalation studies. CONCLUSIONS: Daily on-line IGRT with stereoscopic X-ray imaging allowed a consistent PTV margin reduction considering residual interfraction prostate localization error and intrafraction motion. X-ray offers the best compromise among accuracy, reliability, dose to the patient, and time investment for daily IGRT treatment of prostate.

Image-guided radiotherapy for prostate cancer using 3 different techniques : localization data of 186 patients / C. Garibaldi, B.A. Jereczek, D. Zerini, R. Cambria, A. Ferrari, F. Serafini, F. Cattani, B. Tagaste, C. Fodor, R. Luraschi, R. Orecchia. - In: TUMORI. - ISSN 0300-8916. - 101:3(2015), pp. 273-280. [10.5301/tj.5000322]

Image-guided radiotherapy for prostate cancer using 3 different techniques : localization data of 186 patients

B.A. Jereczek
Secondo
;
R. Orecchia
Ultimo
2015

Abstract

AIMS AND BACKGROUND: This study evaluates 3 different imaging modalities--ultrasound (US), stereoscopic X-ray imaging of implanted markers (Visicoils) (X-ray), and kV cone-beam computed tomography (CBCT)--to assess interfraction and intrafraction localization error during conformal radiation therapy of prostate cancer. METHODS AND STUDY DESIGN: The study population consisted of 186 consecutive prostate cancer patients treated with an image-guided radiotherapy (IGRT) hypofractionated protocol using 3 techniques: 32 with X-ray, 30 with CBCT, and 124 with US. Treatment dose of 70.2 Gy was delivered in 26 fractions with a conformal dynamic arcs technique. Interfraction prostate localization errors were determined for the 3 techniques. Moreover, interfraction and intrafraction prostate motion in terms of translations and rotations, as well as residual errors, were determined with X-ray. RESULTS: The systematic and random components of the prostate localization errors were as follows: (1) with X-ray 3.0 ± 3.4, 2.3 ± 2.7, 1.8 ± 2.3 mm in anterior-posterior (AP), superior-inferior (SI), and left-right (LR) directions and 1.8° ± 1.2°, 2.3° ± 1.5°, 2.7° ± 3.1°, for the yaw, roll, and pitch rotations; (2) with CBCT 3.5 ± 4.2, 3.3 ± 3.3, 2.5 ± 3.1 mm in AP, SI, and LR directions; (3) with US 3.7 ± 4.7, 3.4 ± 4.3, 2.3 ± 3.5 mm in AP, SI, and LR directions. Residual errors with X-ray were less than 1 mm in all directions. Intrafraction prostate motion of less than 0.5 mm in LR and of the order of 1 mm in AP and SI directions was found. This led to a significant reduction of the margins, potentially important for dose escalation studies. CONCLUSIONS: Daily on-line IGRT with stereoscopic X-ray imaging allowed a consistent PTV margin reduction considering residual interfraction prostate localization error and intrafraction motion. X-ray offers the best compromise among accuracy, reliability, dose to the patient, and time investment for daily IGRT treatment of prostate.
Aged; Humans; Male; Prostatic Neoplasms; Radiotherapy, Image-Guided; Treatment Outcome; Ultrasonography, Interventional; Cone-Beam Computed Tomography; Dose Fractionation; Radiotherapy Planning, Computer-Assisted
Settore MED/36 - Diagnostica per Immagini e Radioterapia
2015
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/352353
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 10
social impact