Objectives The aim of this report is to show the use of a pedicled bone lid attached to the Schneider membrane of the maxillary sinus as a surgical procedure for removing intrasinus foreign bodies. Materials and methods This case-report describes a 47-year old male patient, presenting to our attention with dental implant displaced into the maxillary sinus. Foreign body removal was performed by means of a rectangular bone lid, traced on the anterolateral wall of the maxillary sinus with a piezoelectric device, albeit preserving an upper attachment pedicle to the intrasinus membrane. Results No postoperative complications were recorded. Conclusions The pedicled bone lid technique, as proposed by Biglioli e Goisis [16], is an effective and reliable surgical procedure for removing foreign bodies from the maxillary sinus with an intraoral approach.

Obiettivi Illustrare l’utilizzo di uno sportello osseo peduncolato alla membrana di Schneider del seno mascellare come tecnica chirurgica per l’approccio intraorale di rimozione di corpi estranei intrasinusali. Materiali e metodi Il caso clinico riguarda un paziente di sesso maschile di 47 anni, inviato alla nostra attenzione con un impianto dentale dislocato nel seno mascellare in assenza di sintomatologia. La rimozione del corpo estraneo migrato è stata effettuata mediante l’esecuzione, con strumentazione piezoelettrica, di uno sportello osseo rettangolare sulla parete antero-laterale del seno mascellare, mantenendo un peduncolo di collegamento superiore con la membrana intrasinusale. Risultati Il decorso postoperatorio è avvenuto in completa assenza di complicanze. Conclusioni Lo sportello osseo peduncolato proposto da Biglioli e Goisis [16] si rivela una tecnica chirurgica affidabile ed efficace per la rimozione di corpi estranei dislocati nei seni mascellari con approccio intraorale.

Sportello osseo peduncolato per la rimozione chirurgica di un impianto dentale dislocato nel seno mascellare: caso clinico = Pedicled bone lid for surgical removal of a dental implant displaced into the maxillary sinus: case report / P. Fusari, N. Mannino, M. Doto, M. Chiapasco. - In: DENTAL CADMOS. - ISSN 0011-8524. - 82:10(2014), pp. 681-687. [10.1016/S0011-8524(14)70240-5]

Sportello osseo peduncolato per la rimozione chirurgica di un impianto dentale dislocato nel seno mascellare: caso clinico = Pedicled bone lid for surgical removal of a dental implant displaced into the maxillary sinus: case report

P. Fusari
Primo
;
N. Mannino
;
M. Doto
Penultimo
;
M. Chiapasco
Ultimo
2014

Abstract

Objectives The aim of this report is to show the use of a pedicled bone lid attached to the Schneider membrane of the maxillary sinus as a surgical procedure for removing intrasinus foreign bodies. Materials and methods This case-report describes a 47-year old male patient, presenting to our attention with dental implant displaced into the maxillary sinus. Foreign body removal was performed by means of a rectangular bone lid, traced on the anterolateral wall of the maxillary sinus with a piezoelectric device, albeit preserving an upper attachment pedicle to the intrasinus membrane. Results No postoperative complications were recorded. Conclusions The pedicled bone lid technique, as proposed by Biglioli e Goisis [16], is an effective and reliable surgical procedure for removing foreign bodies from the maxillary sinus with an intraoral approach.
Obiettivi Illustrare l’utilizzo di uno sportello osseo peduncolato alla membrana di Schneider del seno mascellare come tecnica chirurgica per l’approccio intraorale di rimozione di corpi estranei intrasinusali. Materiali e metodi Il caso clinico riguarda un paziente di sesso maschile di 47 anni, inviato alla nostra attenzione con un impianto dentale dislocato nel seno mascellare in assenza di sintomatologia. La rimozione del corpo estraneo migrato è stata effettuata mediante l’esecuzione, con strumentazione piezoelettrica, di uno sportello osseo rettangolare sulla parete antero-laterale del seno mascellare, mantenendo un peduncolo di collegamento superiore con la membrana intrasinusale. Risultati Il decorso postoperatorio è avvenuto in completa assenza di complicanze. Conclusioni Lo sportello osseo peduncolato proposto da Biglioli e Goisis [16] si rivela una tecnica chirurgica affidabile ed efficace per la rimozione di corpi estranei dislocati nei seni mascellari con approccio intraorale.
displaced dental implants; implant displacement; foreign bodies; paranasal sinus; maxillary sinus
Settore MED/28 - Malattie Odontostomatologiche
2014
Article (author)
File in questo prodotto:
File Dimensione Formato  
Sportello Osseo Impianto Dislocato Seno Mascellare, Dental Cadmos 10-2014.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 3.74 MB
Formato Adobe PDF
3.74 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/350468
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact