Objective: We measured pulmonary edema by thermal indocyanine green-dye double-dilution technique and quantitative computed tomography (CT) in patients with acute respiratory distress syndrome and compared the two techniques. Design and Setting: Prospective human study in a university hospital. Patients: Fourteen mechanically ventilated patients with acute respiratory distress syndrome (nine primary; nine with intubation <7 days). Interventions: All patients underwent a spiral CT of the thorax. We measured pulmonary thermal volume (PTV) and its components, extravascular lung water and pulmonary blood volume, with an integrated fiberoptic monitoring system (COLD Z-021). Measurements and Results: PTV was tightly correlated with lung weight (LW) measured by CT (PTV=0.6875 * LW(CT)+292.77; correlation coefficient=0.91; p<.0001; bias -11 +/- 8%). Neither etiology of acute respiratory distress syndrome (primary vs. secondary) nor days of intubation affected the accuracy of thermal dye dilution in comparison with CT. There was no correlation between the extravascular lung water (12.3 +/- 3.4 mL/kg) and CT distribution of lung tissue compartments. Extravascular lung water and pulmonary blood volume showed good reproducibility in 32 pairs of thermal dye dilution measurements. Conclusions: Measurements of lung edema by thermal indocyanine green-dye double-dilution method show good correlation with those by quantitative computed tomography and good reproducibility in patients with acute respiratory distress syndrome.

Measurement of pulmonary edema in patients with acute respiratory distress syndrome / N. Patroniti, G. Bellani, E. Maggioni, A. Manfio, B. Marcora, A. Pesenti. - In: CRITICAL CARE MEDICINE. - ISSN 0090-3493. - 33:11(2005 Nov), pp. 2547-2554.

Measurement of pulmonary edema in patients with acute respiratory distress syndrome

A. Pesenti
Ultimo
2005

Abstract

Objective: We measured pulmonary edema by thermal indocyanine green-dye double-dilution technique and quantitative computed tomography (CT) in patients with acute respiratory distress syndrome and compared the two techniques. Design and Setting: Prospective human study in a university hospital. Patients: Fourteen mechanically ventilated patients with acute respiratory distress syndrome (nine primary; nine with intubation <7 days). Interventions: All patients underwent a spiral CT of the thorax. We measured pulmonary thermal volume (PTV) and its components, extravascular lung water and pulmonary blood volume, with an integrated fiberoptic monitoring system (COLD Z-021). Measurements and Results: PTV was tightly correlated with lung weight (LW) measured by CT (PTV=0.6875 * LW(CT)+292.77; correlation coefficient=0.91; p<.0001; bias -11 +/- 8%). Neither etiology of acute respiratory distress syndrome (primary vs. secondary) nor days of intubation affected the accuracy of thermal dye dilution in comparison with CT. There was no correlation between the extravascular lung water (12.3 +/- 3.4 mL/kg) and CT distribution of lung tissue compartments. Extravascular lung water and pulmonary blood volume showed good reproducibility in 32 pairs of thermal dye dilution measurements. Conclusions: Measurements of lung edema by thermal indocyanine green-dye double-dilution method show good correlation with those by quantitative computed tomography and good reproducibility in patients with acute respiratory distress syndrome.
acute respiratory distress syndrome; computed tomography; indocyanine green dye; mechanical ventilation; pulmonary edema; extravascular lung water
Settore MED/41 - Anestesiologia
nov-2005
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/341769
Citazioni
  • ???jsp.display-item.citation.pmc??? 20
  • Scopus 62
  • ???jsp.display-item.citation.isi??? 55
social impact