Aims. Although well supported by postmortem studies, the reliability of carotid atherosclerosis as surrogate marker of coronary atherosclerosis has been put in doubt by in vivo studies showing a poor correlation between carotid intima-media thickness (IMT) detected by external carotid ultrasound (ECU) and coronary stenosis assessed by quantitative coronary angiography (QCA). In the present study, we have investigated whether a stronger in vivo correlation between the two arteries can be obtained by using homogeneous variables such as carotid and coronary IMT, detected by ECU and intravascular ultrasound (IVUS), respectively. Methods and results. ECU, QCA, and IVUS measurements were made in 48 patients. Carotid IMT was correlated with both angiographic and IVUS findings. A significant but weak correlation was observed between ECU and QCA variables (r = 0.35, P < 0.05); the correlation between ECU and IVUS measurements of IMT was higher, with correlation coefficients ranging from 0.49 to 0.55. In patients with a QCA diagnosis of normal/intermediate coronary atherosclerosis, the presence of a carotid-IMT mean > 1 mm was associated with an 18-fold increase in risk of having a positive IVUS test (OR = 17.99, 95% CI 1.83–177.14, P = 0.013) and with a seven-fold increased risk of having a significant IVUS coronary stenosis (OR = 7.4, 95% CI 1.27–44.0, P = 0.028). Conclusion. Carotid atherosclerosis correlates better with coronary atherosclerosis when both circulations are investigated by the same technique (ultrasound) using the same parameter (IMT). This supports the concept that carotid IMT is a good surrogate marker of coronary atherosclerosis.

Carotid intima-media thickness by B-mode ultrasound as surrogate of coronary atherosclerosis: correlation with quantitative coronary angiography and coronary intravascular ultrasound findings / M. Amato, P. Montorsi, A. Ravani, E. Oldani, S. Galli, P.M. Ravagnani, E. Tremoli, D. Baldassarre. - In: EUROPEAN HEART JOURNAL. - ISSN 0195-668X. - 28:17(2007), pp. 2094-2101. [10.1093/eurheartj/ehm244]

Carotid intima-media thickness by B-mode ultrasound as surrogate of coronary atherosclerosis: correlation with quantitative coronary angiography and coronary intravascular ultrasound findings

P. Montorsi
Secondo
;
E. Tremoli
Penultimo
;
D. Baldassarre
Ultimo
2007

Abstract

Aims. Although well supported by postmortem studies, the reliability of carotid atherosclerosis as surrogate marker of coronary atherosclerosis has been put in doubt by in vivo studies showing a poor correlation between carotid intima-media thickness (IMT) detected by external carotid ultrasound (ECU) and coronary stenosis assessed by quantitative coronary angiography (QCA). In the present study, we have investigated whether a stronger in vivo correlation between the two arteries can be obtained by using homogeneous variables such as carotid and coronary IMT, detected by ECU and intravascular ultrasound (IVUS), respectively. Methods and results. ECU, QCA, and IVUS measurements were made in 48 patients. Carotid IMT was correlated with both angiographic and IVUS findings. A significant but weak correlation was observed between ECU and QCA variables (r = 0.35, P < 0.05); the correlation between ECU and IVUS measurements of IMT was higher, with correlation coefficients ranging from 0.49 to 0.55. In patients with a QCA diagnosis of normal/intermediate coronary atherosclerosis, the presence of a carotid-IMT mean > 1 mm was associated with an 18-fold increase in risk of having a positive IVUS test (OR = 17.99, 95% CI 1.83–177.14, P = 0.013) and with a seven-fold increased risk of having a significant IVUS coronary stenosis (OR = 7.4, 95% CI 1.27–44.0, P = 0.028). Conclusion. Carotid atherosclerosis correlates better with coronary atherosclerosis when both circulations are investigated by the same technique (ultrasound) using the same parameter (IMT). This supports the concept that carotid IMT is a good surrogate marker of coronary atherosclerosis.
Angiography; Carotid; Coronary; IVUS; Ultrasound
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
Settore BIO/14 - Farmacologia
2007
http://www.ncbi.nlm.nih.gov/entrez/utils/fref.fcgi?PrId=3051&itool=AbstractPlus-def&uid=17597051&db=pubmed&url=http://eurheartj.oxfordjournals.org/cgi/pmidlookup?view=long&pmid=17597051
Article (author)
File in questo prodotto:
File Dimensione Formato  
030 IVUS 2007.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 328.07 kB
Formato Adobe PDF
328.07 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/33799
Citazioni
  • ???jsp.display-item.citation.pmc??? 44
  • Scopus 165
  • ???jsp.display-item.citation.isi??? 148
social impact