Pyrogallol Red Molybdate (PRM) is the commonest assay used for evaluation of the concentration of feline urinary protein (UP). The use of Coomassie Brillant Blu (CBB) assay is also reported but data about method-dependent differences and analytical variability are lacking. Therefore, the aims of this study were to compare UPs and urinary protein:creatinine (UPC) ratios recorded with PRM and CBB and to evaluate intra-assay imprecision of creatinine, proteinuria and UPC ratio of both methods in cats. Urine samples were collected from 58 client-owned cats by ultrasonographically-guided cystocentesis and centrifuged within 30 minutes. Due to the analytical nature of this study, samples were included irrespective of results of sediment or of underlining diseases. Creatininuria was measured with the modified Jaffè method and UPs with PRM and CBB in triplicate. The mean values were used to calculate UPC ratios. The Wilcoxon signed rank test was performed to investigate the differences between UP obtained with PRR and CBB and between calculated UPC ratios. Correlation between methods was assessed with the Spearman test and agreement with Passing-Bablok and Bland-Altman tests. Intra-assay coefficients of variations (CV) were calculated in 15 samples by 20 repeated measurements of creatinine and of UPs (with both methods). The Spearman test was used to investigate the correlation between mean UPs and intra-assay CVs for PRM and CBB. Concordance between UPC ratios of both methods in classifying patients as proteinuric (P, UPC ratio <0,2), borderline proteinuric (BP, 0,2< UPC ratio <0,4) or non proteinuric (NP, UPC ratio >0,4) was assessed using Cohen’s k coefficient test. UPs assayed with PRM and CBB ranged from 6,2 to 193,6 mg/dL (median 28,8 mg/dL) and from 8,9 to 325,4 mg/dL (median 61,6 mg/dL), respectively, and creatinine concentration from 28,2 to 934,2 mg/dL (median 199,3 mg/dL). Proteinuria and UPC ratio showed statistically significant differences between methods (p<0,0001 for both) with higher values recorded using the CBB method. Agreement between methods showed constant and proportional error for protein quantification. The two methods were correlated for both UP and UPC (p<0,0001). All intra-assay CV were <10%. No correlations were found between the mean UP and the intra-assay CV for both PRM and CBB. Concordance in classifying samples according to IRIS sub-staging was moderate (k=0,476). Coomassie Blu method was accurate and precise at any level of proteinuria but the higher UPC obtained with CBB compared to PRM may affect interpretation and clinical decisions according to the IRIS guidelines.

Evaluation of proteinuria in cats: comparison between Coomassie Brilliant Blue and Pyrogallol Red Molybdate / M. Giraldi, G. Rossi, W. Bertazzolo, S. Paltrinieri, P. Scarpa - In: Proceedings of the 25th ECVIM-CA Congress[s.l] : ECVIM-CA congress, 2015 Sep 10. - pp. 177-177 (( convegno ECVIM - CA CONGRESS tenutosi a Lisbon nel 2015.

Evaluation of proteinuria in cats: comparison between Coomassie Brilliant Blue and Pyrogallol Red Molybdate

M. Giraldi
Primo
;
S. Paltrinieri
Penultimo
;
P. Scarpa
Ultimo
2015

Abstract

Pyrogallol Red Molybdate (PRM) is the commonest assay used for evaluation of the concentration of feline urinary protein (UP). The use of Coomassie Brillant Blu (CBB) assay is also reported but data about method-dependent differences and analytical variability are lacking. Therefore, the aims of this study were to compare UPs and urinary protein:creatinine (UPC) ratios recorded with PRM and CBB and to evaluate intra-assay imprecision of creatinine, proteinuria and UPC ratio of both methods in cats. Urine samples were collected from 58 client-owned cats by ultrasonographically-guided cystocentesis and centrifuged within 30 minutes. Due to the analytical nature of this study, samples were included irrespective of results of sediment or of underlining diseases. Creatininuria was measured with the modified Jaffè method and UPs with PRM and CBB in triplicate. The mean values were used to calculate UPC ratios. The Wilcoxon signed rank test was performed to investigate the differences between UP obtained with PRR and CBB and between calculated UPC ratios. Correlation between methods was assessed with the Spearman test and agreement with Passing-Bablok and Bland-Altman tests. Intra-assay coefficients of variations (CV) were calculated in 15 samples by 20 repeated measurements of creatinine and of UPs (with both methods). The Spearman test was used to investigate the correlation between mean UPs and intra-assay CVs for PRM and CBB. Concordance between UPC ratios of both methods in classifying patients as proteinuric (P, UPC ratio <0,2), borderline proteinuric (BP, 0,2< UPC ratio <0,4) or non proteinuric (NP, UPC ratio >0,4) was assessed using Cohen’s k coefficient test. UPs assayed with PRM and CBB ranged from 6,2 to 193,6 mg/dL (median 28,8 mg/dL) and from 8,9 to 325,4 mg/dL (median 61,6 mg/dL), respectively, and creatinine concentration from 28,2 to 934,2 mg/dL (median 199,3 mg/dL). Proteinuria and UPC ratio showed statistically significant differences between methods (p<0,0001 for both) with higher values recorded using the CBB method. Agreement between methods showed constant and proportional error for protein quantification. The two methods were correlated for both UP and UPC (p<0,0001). All intra-assay CV were <10%. No correlations were found between the mean UP and the intra-assay CV for both PRM and CBB. Concordance in classifying samples according to IRIS sub-staging was moderate (k=0,476). Coomassie Blu method was accurate and precise at any level of proteinuria but the higher UPC obtained with CBB compared to PRM may affect interpretation and clinical decisions according to the IRIS guidelines.
Settore VET/08 - Clinica Medica Veterinaria
Settore VET/03 - Patologia Generale e Anatomia Patologica Veterinaria
10-set-2015
EUROPEAN COLLEGE OF VETERINARY INTERNAL MEDICINE
EUROPEAN COLLEGE OF VETERINARY CLINICAL PATHOLOGY
EUROPEAN COLLEGE OF VETERINARY NEPHROLOGY AND UROLOGY
http://www.ecvimcongress.org/abstracts/awards_lisbon_2015
Book Part (author)
File in questo prodotto:
File Dimensione Formato  
ecvim_2015_piro_blu_cat.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 118.88 kB
Formato Adobe PDF
118.88 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/331290
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact