BACKGROUND AND AIMS: Reports on imaging of active Crohn's disease (aCD) using contrast-enhanced ultrasound (CEUS) are encouraging. However, the statistical power of most published papers is limited due to the small size of the patient groups included. This study was performed to verify the diagnostic value of CEUS in detecting aCD. METHODS: A systematic literature search was performed by two independent reviewers for articles on the test characteristics of CEUS for the identification of aCD. The quality of the analysed studies was evaluated using a quality assessment tool for diagnostic accuracy studies (QUADAS-2). Pooling was performed using a diagnostic random-effect model and bivariate analysis. RESULTS: Eight articles were included in the final analysis, with a total of 332 patients. There was no significant publication bias. Significant heterogeneity was found regarding CEUS methodology and sonographic definitions of aCD. In a bivariate analysis, pooled sensitivity was 0.94 (95% CI 0.87-0.97) and pooled specificity was 0.79 (95% CI 0.67-0.88). Spearman correlation statistics presented no significant diagnostic threshold effect (r = 0.12, p > 0.9). Subgroup analysis showed that relative intestine wall enhancement had the highest diagnostic value (area under the curve 94%), while the presence of enhancement and analysis of the slope were less useful (area under the curve 91 and 90%, respectively). CONCLUSIONS: CEUS presents good sensitivity and moderate specificity in the detection of the aCD. Large-scale randomized trials with quantitative evaluation of CEUS images are necessary to promote this technique in clinical practice.

Contrast-enhanced ultrasound for detection of Crohn's disease activity: systematic review and meta-analysis / Z. Serafin, M. Białecki, A. Białecka, L.M. Sconfienza, M. Klopocka. - In: JOURNAL OF CROHN'S AND COLITIS. - ISSN 1873-9946. - 10:3(2016 Mar), pp. 354-362.

Contrast-enhanced ultrasound for detection of Crohn's disease activity: systematic review and meta-analysis

L.M. Sconfienza
Penultimo
;
2016

Abstract

BACKGROUND AND AIMS: Reports on imaging of active Crohn's disease (aCD) using contrast-enhanced ultrasound (CEUS) are encouraging. However, the statistical power of most published papers is limited due to the small size of the patient groups included. This study was performed to verify the diagnostic value of CEUS in detecting aCD. METHODS: A systematic literature search was performed by two independent reviewers for articles on the test characteristics of CEUS for the identification of aCD. The quality of the analysed studies was evaluated using a quality assessment tool for diagnostic accuracy studies (QUADAS-2). Pooling was performed using a diagnostic random-effect model and bivariate analysis. RESULTS: Eight articles were included in the final analysis, with a total of 332 patients. There was no significant publication bias. Significant heterogeneity was found regarding CEUS methodology and sonographic definitions of aCD. In a bivariate analysis, pooled sensitivity was 0.94 (95% CI 0.87-0.97) and pooled specificity was 0.79 (95% CI 0.67-0.88). Spearman correlation statistics presented no significant diagnostic threshold effect (r = 0.12, p > 0.9). Subgroup analysis showed that relative intestine wall enhancement had the highest diagnostic value (area under the curve 94%), while the presence of enhancement and analysis of the slope were less useful (area under the curve 91 and 90%, respectively). CONCLUSIONS: CEUS presents good sensitivity and moderate specificity in the detection of the aCD. Large-scale randomized trials with quantitative evaluation of CEUS images are necessary to promote this technique in clinical practice.
CEUS; Crohn’s Disease; Meta-analysis
Settore MED/36 - Diagnostica per Immagini e Radioterapia
Settore MED/12 - Gastroenterologia
mar-2016
ott-2015
Article (author)
File in questo prodotto:
File Dimensione Formato  
354.full.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 825.79 kB
Formato Adobe PDF
825.79 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/330384
Citazioni
  • ???jsp.display-item.citation.pmc??? 15
  • Scopus 60
  • ???jsp.display-item.citation.isi??? 56
social impact