Autologous saphenous veins are commonly used for the coronary artery bypass grafting even if they are liable to progressive patency reduction, known as 'vein graft disease'. Although several cellular and molecular causes for vein graft disease have been identified using in vivo models, the metabolic cues induced by sudden interruption of vasa vasorum blood supply have remained unexplored. In the present manuscript, we describe the design of an ex vivo culture system allowing the generation of an oxygen gradient between the luminal and the adventitial sides of the vein. This system featured a separation between the inner and the outer vessel culture circuits, and integrated a purpose-developed de-oxygenator module enabling the trans-wall oxygen distribution (high oxygen level at luminal side and low oxygen level at the adventitial side) existing in arterialized veins. Compared with standard cultures the bypass-specific conditions determined a significant increase in the proliferation of cells around adventitial vasa vasorum and an elevation in the length density of small and large caliber vasa vasorum. These results suggest, for the first time, a cause-effect relationship between the vein adventitial hypoxia and a neo-vascularization process, a factor known to predispose the arterialized vein conduits to restenosis.

Human saphenous vein response to trans-wall oxygen gradients in a novel ex vivo conditioning platform / M. Piola, F. Prandi, G.B. Fiore, M. Agrifoglio, G. Polvani, M. Pesce, M. Soncini. - In: ANNALS OF BIOMEDICAL ENGINEERING. - ISSN 0090-6964. - 44:5(2016 May), pp. 1449-1461. [10.1007/s10439-015-1434-0]

Human saphenous vein response to trans-wall oxygen gradients in a novel ex vivo conditioning platform

M. Agrifoglio;G. Polvani;
2016

Abstract

Autologous saphenous veins are commonly used for the coronary artery bypass grafting even if they are liable to progressive patency reduction, known as 'vein graft disease'. Although several cellular and molecular causes for vein graft disease have been identified using in vivo models, the metabolic cues induced by sudden interruption of vasa vasorum blood supply have remained unexplored. In the present manuscript, we describe the design of an ex vivo culture system allowing the generation of an oxygen gradient between the luminal and the adventitial sides of the vein. This system featured a separation between the inner and the outer vessel culture circuits, and integrated a purpose-developed de-oxygenator module enabling the trans-wall oxygen distribution (high oxygen level at luminal side and low oxygen level at the adventitial side) existing in arterialized veins. Compared with standard cultures the bypass-specific conditions determined a significant increase in the proliferation of cells around adventitial vasa vasorum and an elevation in the length density of small and large caliber vasa vasorum. These results suggest, for the first time, a cause-effect relationship between the vein adventitial hypoxia and a neo-vascularization process, a factor known to predispose the arterialized vein conduits to restenosis.
Coronary artery bypass grafting; De-oxygenator system; Oxygen conditioning; Saphenous vein graft disease; Vessel culture system; neo-Vascularization
Settore MED/23 - Chirurgia Cardiaca
mag-2016
29-ago-2015
Article (author)
File in questo prodotto:
File Dimensione Formato  
art%3A10.1007%2Fs10439-015-1434-0.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 7.28 MB
Formato Adobe PDF
7.28 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/313459
Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 11
social impact