The accuracy of computed tomography (CT) for assessment of coronary stents is as yet unproven and radiation exposure has been a concern. The aim of our study is to compare radiation dose and diagnostic performance of CT with prospective ECG-triggering versus retrospective ECG-triggering for the detection of in-stent restenosis (ISR). We enrolled 168 consecutive patients with suspected ISR, 83 studied using CT with prospective ECG-triggering (group 1) and 85 using retrospective ECG-triggering (group 2). Prevalence of ISR according to catheter angiography was 24% in both groups. The overall evaluability was similar (93% in group 1 vs 95% in group 2). Artefact sub-analysis showed a significantly lower number of blooming and higher number of slice misalignment in group 1 vs group 2. In the stent-based analysis using only evaluable stents, specificity, positive predictive value and accuracy were significantly higher in group 1 (100%, 100% and 99%, respectively) than in group 2 (97%, 91% and 95%, respectively, p < 0.05). Group 1 was exposed to a lower radiation dose compared with group 2 (4.3 +/- 1.4 mSv vs 18.5 +/- 5.5 mSv, p < 00.1). CT with prospective ECG-triggering can improve diagnostic accuracy of non-invasive imaging of coronary stents with a significant reduction in radiation exposure.

High diagnostic accuracy of prospective ECG-gating 64-slice computed tomography coronary angiography for the detection of in-stent restenosis / D. Andreini, G. Pontone, A. Bartorelli, S. Mushtaq, D. Trabattoni, E. Bertella, S. Cortinovis, A. Annoni, A. Formenti, G. Ballerini, P. Agostoni, C. Fiorentini, M. Pepi. - In: EUROPEAN RADIOLOGY. - ISSN 0938-7994. - 21:7(2011 Jul), pp. 1430-1438. [10.1007/s00330-011-2085-7]

High diagnostic accuracy of prospective ECG-gating 64-slice computed tomography coronary angiography for the detection of in-stent restenosis

D. Andreini;G. Pontone;A. Bartorelli;P. Agostoni;C. Fiorentini;
2011

Abstract

The accuracy of computed tomography (CT) for assessment of coronary stents is as yet unproven and radiation exposure has been a concern. The aim of our study is to compare radiation dose and diagnostic performance of CT with prospective ECG-triggering versus retrospective ECG-triggering for the detection of in-stent restenosis (ISR). We enrolled 168 consecutive patients with suspected ISR, 83 studied using CT with prospective ECG-triggering (group 1) and 85 using retrospective ECG-triggering (group 2). Prevalence of ISR according to catheter angiography was 24% in both groups. The overall evaluability was similar (93% in group 1 vs 95% in group 2). Artefact sub-analysis showed a significantly lower number of blooming and higher number of slice misalignment in group 1 vs group 2. In the stent-based analysis using only evaluable stents, specificity, positive predictive value and accuracy were significantly higher in group 1 (100%, 100% and 99%, respectively) than in group 2 (97%, 91% and 95%, respectively, p < 0.05). Group 1 was exposed to a lower radiation dose compared with group 2 (4.3 +/- 1.4 mSv vs 18.5 +/- 5.5 mSv, p < 00.1). CT with prospective ECG-triggering can improve diagnostic accuracy of non-invasive imaging of coronary stents with a significant reduction in radiation exposure.
No
English
Computed tomography; Coronary stents; Radiation dose; Invasive coronary angiography; In-stent restenosis; Coronary arteries
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
Articolo
Esperti anonimi
Pubblicazione scientifica
lug-2011
21
7
1430
1438
9
Pubblicato
Periodico con rilevanza internazionale
Aderisco
info:eu-repo/semantics/article
High diagnostic accuracy of prospective ECG-gating 64-slice computed tomography coronary angiography for the detection of in-stent restenosis / D. Andreini, G. Pontone, A. Bartorelli, S. Mushtaq, D. Trabattoni, E. Bertella, S. Cortinovis, A. Annoni, A. Formenti, G. Ballerini, P. Agostoni, C. Fiorentini, M. Pepi. - In: EUROPEAN RADIOLOGY. - ISSN 0938-7994. - 21:7(2011 Jul), pp. 1430-1438. [10.1007/s00330-011-2085-7]
reserved
Prodotti della ricerca::01 - Articolo su periodico
13
262
Article (author)
si
D. Andreini, G. Pontone, A. Bartorelli, S. Mushtaq, D. Trabattoni, E. Bertella, S. Cortinovis, A. Annoni, A. Formenti, G. Ballerini, P. Agostoni, C. F...espandi
File in questo prodotto:
File Dimensione Formato  
art%3A10.1007%2Fs00330-011-2085-7.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 222.92 kB
Formato Adobe PDF
222.92 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/297221
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 24
  • ???jsp.display-item.citation.isi??? 22
  • OpenAlex ND
social impact