Objective: To determine the accuracy of an immunochromatographic cartridge (IC) test for blood typing feline type A, B, and AB blood samples. Design: Prospective observational study. Setting: University teaching hospital. Samples: Fifty-one nonanemic and 19 anemic feline blood samples. Interventions: Samples were blood typed by both card agglutination (CA) and IC techniques. Discordant results were analyzed using a back-typing technique for the presence of alloantibodies. Repeatability and reproducibility of the IC method were evaluated. Accuracy of the IC method was determined for feline whole blood anticoagulated with EDTA and citrate phosphate dextrose adenine (CPDA1), for feline-packed RBCs with CPDA1 and saline adenine glucose-mannitol, and for autoagglutinated and hemolytic samples. Accuracy of IC testing was determined for feline blood after room temperature, 4 ± 2, -20, and -80°C storage following 24, 48, 72, and 96 hours, and after 1, 2, 3, and 4 weeks of storage. Measurements and Main Results: In anemic and nonanemic samples the IC technique had a specificity, sensitivity, positive predictive value, and negative predictive value of 100% in detecting feline blood types A, B, and AB, outperforming a CA test. Results were repeatable and reproducible. Using IC it was possible to blood type samples anticoagulated with EDTA and CPDA1, packed RBC samples with CPDA1 and saline adenine glucose-mannitol, autoagglutinated and hemolytic samples, and samples stored at 4 ± 2°C and at room temperature for up to 1 month. Conclusions: The IC technique is an accurate assay for the identification of A, B, and AB blood types in anemic and nonanemic feline blood. It has a higher sensitivity and specificity than the CA test, and can be used in samples stored with common anticoagulants or preservative solutions used in feline transfusion medicine.

Evaluation of an immunochromatographic test for feline AB system blood typing / E. Spada, D. Proverbio, L. Baggiani, G. Bagnagatti De Giorgi, R. Perego, E. Ferro. - In: JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE. - ISSN 1479-3261. - 26:1(2016 Jan), pp. 137-141. [10.1111/vec.12360]

Evaluation of an immunochromatographic test for feline AB system blood typing

E. Spada
Primo
;
D. Proverbio
Secondo
;
G. Bagnagatti De Giorgi;R. Perego
Penultimo
;
E. Ferro
Ultimo
2016

Abstract

Objective: To determine the accuracy of an immunochromatographic cartridge (IC) test for blood typing feline type A, B, and AB blood samples. Design: Prospective observational study. Setting: University teaching hospital. Samples: Fifty-one nonanemic and 19 anemic feline blood samples. Interventions: Samples were blood typed by both card agglutination (CA) and IC techniques. Discordant results were analyzed using a back-typing technique for the presence of alloantibodies. Repeatability and reproducibility of the IC method were evaluated. Accuracy of the IC method was determined for feline whole blood anticoagulated with EDTA and citrate phosphate dextrose adenine (CPDA1), for feline-packed RBCs with CPDA1 and saline adenine glucose-mannitol, and for autoagglutinated and hemolytic samples. Accuracy of IC testing was determined for feline blood after room temperature, 4 ± 2, -20, and -80°C storage following 24, 48, 72, and 96 hours, and after 1, 2, 3, and 4 weeks of storage. Measurements and Main Results: In anemic and nonanemic samples the IC technique had a specificity, sensitivity, positive predictive value, and negative predictive value of 100% in detecting feline blood types A, B, and AB, outperforming a CA test. Results were repeatable and reproducible. Using IC it was possible to blood type samples anticoagulated with EDTA and CPDA1, packed RBC samples with CPDA1 and saline adenine glucose-mannitol, autoagglutinated and hemolytic samples, and samples stored at 4 ± 2°C and at room temperature for up to 1 month. Conclusions: The IC technique is an accurate assay for the identification of A, B, and AB blood types in anemic and nonanemic feline blood. It has a higher sensitivity and specificity than the CA test, and can be used in samples stored with common anticoagulants or preservative solutions used in feline transfusion medicine.
cat; feline neonatal isoerythrolysis; transfusion medicine; transfusion reaction
Settore VET/08 - Clinica Medica Veterinaria
gen-2016
11-ago-2015
Article (author)
File in questo prodotto:
File Dimensione Formato  
Spada_et_al-2015-Journal_of_Veterinary_Emergency_and_Critical_Care.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 158.77 kB
Formato Adobe PDF
158.77 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Spada et al. Evaluation of an immunocromatographic test for feline AB system blood typing Green OA.pdf

accesso aperto

Tipologia: Post-print, accepted manuscript ecc. (versione accettata dall'editore)
Dimensione 85.55 kB
Formato Adobe PDF
85.55 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/295418
Citazioni
  • ???jsp.display-item.citation.pmc??? 15
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 16
social impact