Devices used in future experiments at LHC will have to work in a very hostile environment. Power supply is a key aspect in this scenario and new converters must be designed in order to meet the future requirements. This is particularly true for Point of Load (PoL) converters that, being located as close as possible to the loads, must operate in a very harsh environment. This paper presents an experimental activity aimed to verify the compliance with a high stationary magnetic field of a commercial PoL, as well as experimental measurements aimed to test the performance of new GaN power devices used in PoL converters. In particular, a highly integrated commercial PoL converter, that includes in the same package the output filter inductor, is considered for the magnetic test, while an ad-hoc PoL converter, employing 40 V, 33 A normally off GaN MOSFETs has been designed and, finally, tested. Dynamic RDSon measurements of the same devices are also included.

Testing the behaviour in hostile environment of Points of Load for LHC experiments / M. Lazzaroni, M. Citterio, S. Latorre, A. Lanza, G. Spiazzi. - In: MEASUREMENT. - ISSN 0263-2241. - 75(2015 Nov), pp. 161-170.

Testing the behaviour in hostile environment of Points of Load for LHC experiments

M. Lazzaroni
;
2015

Abstract

Devices used in future experiments at LHC will have to work in a very hostile environment. Power supply is a key aspect in this scenario and new converters must be designed in order to meet the future requirements. This is particularly true for Point of Load (PoL) converters that, being located as close as possible to the loads, must operate in a very harsh environment. This paper presents an experimental activity aimed to verify the compliance with a high stationary magnetic field of a commercial PoL, as well as experimental measurements aimed to test the performance of new GaN power devices used in PoL converters. In particular, a highly integrated commercial PoL converter, that includes in the same package the output filter inductor, is considered for the magnetic test, while an ad-hoc PoL converter, employing 40 V, 33 A normally off GaN MOSFETs has been designed and, finally, tested. Dynamic RDSon measurements of the same devices are also included.
No
English
Current measurement; Measurement; Point of Load; Reliability; Testing; Voltage measurement
Settore ING-INF/07 - Misure Elettriche e Elettroniche
Articolo
Esperti anonimi
Ricerca applicata
Pubblicazione scientifica
nov-2015
Elsevier
75
161
170
10
Pubblicato
Periodico con rilevanza internazionale
crossref
NON aderisco
info:eu-repo/semantics/article
Testing the behaviour in hostile environment of Points of Load for LHC experiments / M. Lazzaroni, M. Citterio, S. Latorre, A. Lanza, G. Spiazzi. - In: MEASUREMENT. - ISSN 0263-2241. - 75(2015 Nov), pp. 161-170.
none
Prodotti della ricerca::01 - Articolo su periodico
5
262
Article (author)
si
M. Lazzaroni, M. Citterio, S. Latorre, A. Lanza, G. Spiazzi
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/293710
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 4
social impact