Purpose: The authors sought to evaluate the effect of model-based iterative reconstruction (MBIR) on the sensitivity of ground-glass nodule (GGN) detection at different dose levels.Materials and methods: Fifty-four artificial GGN were randomly divided into three sets, each positioned in an anthropomorphic phantom. The three sets were evaluated on standard-dose (SD, 350 mA), low-dose (LD, 35 mA) and ultra-low-dose (ULD, 10 mA) CT scans (100 kV, 64 × 0.625 mm, 0.5 s), and each scan was reconstructed twice with filtered back projection (FBP) and MBIR. Three radiologists independently evaluated the scans for GGN presence and size. SD + FBP was considered the reference standard. A region of interest (ROI) was used to calculate signal-to-noise ratio (SNR) and contrast-to-noise ratio normalised to dose (CNRD). McNemar’s test, Bland–Altman analysis and t test were used for statistical assessment (p < 0.05).Results: The mean diameter of the 54 GGNs was 9.2 mm (range 3.7–17.3 mm). For the three readers, no statistically significant differences were observed in the sensitivity of GGN detection between LD + MBIR, ULD + MBIR and SD + FBP (p > 0.05). Bland–Altman analysis showed a good reader agreement (±1.5 mm) for GGN size between SD + FBP and ULD + MBIR. For low dose and ultra-low dose, the SNR and CNRD were significantly higher with MBIR (p < 0.0001). The effective dose was 97.1 % lower with ultra-low dose (0.15 mSv) than standard dose (5.15 mSv).Conclusions: The detection of GGN with MBIR at low-dose and ultra-low-dose CT does not differ significantly from standard-dose CT with FBP in an anthropomorphic phantom.

Ultra-low-dose CT with model-based iterative reconstruction (MBIR): detection of ground-glass nodules in an anthropomorphic phantom study / C. Rampinelli, D. Origgi, V. Vecchi, L. Funicelli, S. Raimondi, P. Deak, M. Bellomi. - In: LA RADIOLOGIA MEDICA. - ISSN 0033-8362. - 120:7(2015 Jul), pp. 611-617. [10.1007/s11547-015-0505-5]

Ultra-low-dose CT with model-based iterative reconstruction (MBIR): detection of ground-glass nodules in an anthropomorphic phantom study

V. Vecchi;M. Bellomi
Ultimo
2015

Abstract

Purpose: The authors sought to evaluate the effect of model-based iterative reconstruction (MBIR) on the sensitivity of ground-glass nodule (GGN) detection at different dose levels.Materials and methods: Fifty-four artificial GGN were randomly divided into three sets, each positioned in an anthropomorphic phantom. The three sets were evaluated on standard-dose (SD, 350 mA), low-dose (LD, 35 mA) and ultra-low-dose (ULD, 10 mA) CT scans (100 kV, 64 × 0.625 mm, 0.5 s), and each scan was reconstructed twice with filtered back projection (FBP) and MBIR. Three radiologists independently evaluated the scans for GGN presence and size. SD + FBP was considered the reference standard. A region of interest (ROI) was used to calculate signal-to-noise ratio (SNR) and contrast-to-noise ratio normalised to dose (CNRD). McNemar’s test, Bland–Altman analysis and t test were used for statistical assessment (p < 0.05).Results: The mean diameter of the 54 GGNs was 9.2 mm (range 3.7–17.3 mm). For the three readers, no statistically significant differences were observed in the sensitivity of GGN detection between LD + MBIR, ULD + MBIR and SD + FBP (p > 0.05). Bland–Altman analysis showed a good reader agreement (±1.5 mm) for GGN size between SD + FBP and ULD + MBIR. For low dose and ultra-low dose, the SNR and CNRD were significantly higher with MBIR (p < 0.0001). The effective dose was 97.1 % lower with ultra-low dose (0.15 mSv) than standard dose (5.15 mSv).Conclusions: The detection of GGN with MBIR at low-dose and ultra-low-dose CT does not differ significantly from standard-dose CT with FBP in an anthropomorphic phantom.
Computed tomography; Ground-glass nodules; Iterative reconstruction; Radiation exposure dose
Settore MED/36 - Diagnostica per Immagini e Radioterapia
lug-2015
6-feb-2015
Article (author)
File in questo prodotto:
File Dimensione Formato  
art%3A10.1007%2Fs11547-015-0505-5.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 652.85 kB
Formato Adobe PDF
652.85 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
art%3A10.1007%2Fs11547-015-0505-5.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 800.54 kB
Formato Adobe PDF
800.54 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/271586
Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 17
social impact