This paper describes a method of determining clioquinol levels in hamster plasma and tissue by means of HPLC and electrochemical detection. Clioquinol was separated on a Nucleosil C18 300 x 3.9 mm I.D. 7 µm column at 1 ml/min using a phosphate/citrate buffer 0.1 M (400 ml) with 600 ml of a methanol:acetonitrile (1:1, v/v) mobile phase. The retention times of clioquinol and the IS were respectively 11.6 and 8.1 min; the quantitation limit (CV>8%) was 5 ng/ml in plasma and 10 ng/ml in tissues. The intra- and inter-assay accuracies of the method were more than 95%, with coefficients of variation between 3.0% to 7.7%, and plasma and tissue recovery rates of 72-77%. There was a linear response to clioquinol 5-2000 ng/ml in plasma, and 10-1000 ng/g in tissues. The method is highly sensitive and selective, makes it possible to study the pharmacokinetics of plasma clioquinol after oral administration and the distribution of clioquinol in tissues, and could be used to monitor plasma clioquinol levels in humans.

Determination of 5-chloro-7-iodo-8-quinolinol (clioquinol) in plasma and tissues of hamsters by high-performance liquid chromatography and electrochemical detection / G. Bondiolotti, C. Pollera, R.M. Pirola, S.R.C. Bareggi. - In: JOURNAL OF CHROMATOGRAPHY. B. - ISSN 1570-0232. - 837:1-2(2006 Apr 14), pp. 87-91. [10.1016/j.jchromb.2006.04.014]

Determination of 5-chloro-7-iodo-8-quinolinol (clioquinol) in plasma and tissues of hamsters by high-performance liquid chromatography and electrochemical detection

G. Bondiolotti
Primo
;
C. Pollera
Secondo
;
R.M. Pirola
Penultimo
;
S.R.C. Bareggi
Ultimo
2006

Abstract

This paper describes a method of determining clioquinol levels in hamster plasma and tissue by means of HPLC and electrochemical detection. Clioquinol was separated on a Nucleosil C18 300 x 3.9 mm I.D. 7 µm column at 1 ml/min using a phosphate/citrate buffer 0.1 M (400 ml) with 600 ml of a methanol:acetonitrile (1:1, v/v) mobile phase. The retention times of clioquinol and the IS were respectively 11.6 and 8.1 min; the quantitation limit (CV>8%) was 5 ng/ml in plasma and 10 ng/ml in tissues. The intra- and inter-assay accuracies of the method were more than 95%, with coefficients of variation between 3.0% to 7.7%, and plasma and tissue recovery rates of 72-77%. There was a linear response to clioquinol 5-2000 ng/ml in plasma, and 10-1000 ng/g in tissues. The method is highly sensitive and selective, makes it possible to study the pharmacokinetics of plasma clioquinol after oral administration and the distribution of clioquinol in tissues, and could be used to monitor plasma clioquinol levels in humans.
English
Clioquinol ; hamsters ; HPLC ; electrochemical detection
Settore VET/05 - Malattie Infettive degli Animali Domestici
Settore BIO/14 - Farmacologia
Articolo
Sì, ma tipo non specificato
14-apr-2006
Elsevier
837
1-2
87
91
Pubblicato
Periodico con rilevanza internazionale
info:eu-repo/semantics/article
Determination of 5-chloro-7-iodo-8-quinolinol (clioquinol) in plasma and tissues of hamsters by high-performance liquid chromatography and electrochemical detection / G. Bondiolotti, C. Pollera, R.M. Pirola, S.R.C. Bareggi. - In: JOURNAL OF CHROMATOGRAPHY. B. - ISSN 1570-0232. - 837:1-2(2006 Apr 14), pp. 87-91. [10.1016/j.jchromb.2006.04.014]
none
Prodotti della ricerca::01 - Articolo su periodico
4
262
Article (author)
si
G. Bondiolotti, C. Pollera, R.M. Pirola, S.R.C. Bareggi
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/26876
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 23
  • ???jsp.display-item.citation.isi??? 23
social impact