Autologous fat graft is becoming a widely used procedure in plastic surgery. Its indications are progressively increasing, ranging from functional to aesthetic surgery. The procedure has now entered in the field of regenerative medicine. Although many have commented on the long-term safety implications of fat grafting, especially to the breast, there is no body of information in the literature that analyzes near-term complications associated with this procedure. We performed a retrospective study of 1000 consecutive fat transplantation cases in our hospital since 2005. Complications were divided between donor-site complications and recipient-site complications. Of 1000 procedures, there were 2 donor-site hematomas and 83 local deformities caused by liposuction. In treated patients, the recipient site, there were 4 infections. One patient reported implant rupture at 1 month after fat graft. There was no skin necrosis in the grafted areas and no systemic complications such as pulmonary embolism, cardiac arrest, or deep venous thrombosis. The complications in fat transplantation are dominated by complications of the liposuction-the donor harvesting phase of the procedure. The relatively low complication rates in the recipient site suggest that fat transplantation, especially considering the recipient, is characterized by a high safety level and our device is simple to use.
Autologous fat graft by needle : analysis of complications after 1000 patients / L. Maione, V. Vinci, M. Klinger, F.M. Klinger, F. Caviggioli. - In: ANNALS OF PLASTIC SURGERY. - ISSN 0148-7043. - 74:3(2015), pp. 277-280. [10.1097/SAP.0000000000000050]
Autologous fat graft by needle : analysis of complications after 1000 patients
L. MaionePrimo
;V. VinciSecondo
;M. Klinger;F.M. Klinger;F. CaviggioliUltimo
2015
Abstract
Autologous fat graft is becoming a widely used procedure in plastic surgery. Its indications are progressively increasing, ranging from functional to aesthetic surgery. The procedure has now entered in the field of regenerative medicine. Although many have commented on the long-term safety implications of fat grafting, especially to the breast, there is no body of information in the literature that analyzes near-term complications associated with this procedure. We performed a retrospective study of 1000 consecutive fat transplantation cases in our hospital since 2005. Complications were divided between donor-site complications and recipient-site complications. Of 1000 procedures, there were 2 donor-site hematomas and 83 local deformities caused by liposuction. In treated patients, the recipient site, there were 4 infections. One patient reported implant rupture at 1 month after fat graft. There was no skin necrosis in the grafted areas and no systemic complications such as pulmonary embolism, cardiac arrest, or deep venous thrombosis. The complications in fat transplantation are dominated by complications of the liposuction-the donor harvesting phase of the procedure. The relatively low complication rates in the recipient site suggest that fat transplantation, especially considering the recipient, is characterized by a high safety level and our device is simple to use.File | Dimensione | Formato | |
---|---|---|---|
00000637-201503000-00003.pdf
accesso riservato
Tipologia:
Publisher's version/PDF
Dimensione
3.63 MB
Formato
Adobe PDF
|
3.63 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.