The position sensitivity of a cylindrical continuous 3″ × 3″ (7.62 cm × 7.62 cm) LaBr3:Ce crystal was studied using a collimated beam of 662 keV gamma rays and a spectroscopic shielded PMT (HAMAMATSU R6233-100SEL) with standard passive voltage divider (HAMAMATSU E1198-26). The used crystal is sealed in a capsule and has diffusive/reflective surfaces to optimize the energy resolution. A complete scan of the crystal was performed with a 5 mm step grid. The data show that, in average, the image, produced by the scintillation light on the photocathode, changes with the source position. By using the measured full energy peak position using three different windows on the PMT it was possible to identify the position of the interaction of the incident gamma ray.

Position sensitivity in a 3″ × 3″ LaBr3:Ce scintillator / A. Giaz, F. Camera, N. Blasi, C. Boiano, S. Brambilla, S. Coelli, B. Million, S. Riboldi, O. Wieland - In: IEEE Nuclear Science Symposium Conference Record[s.l] : Institute of Electrical and Electronics Engineers Inc., 2013. - ISBN 9781479905348. - pp. 1-3 (( convegno 2013 60th IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2013 tenutosi a Seoul, kor nel 2013 [10.1109/NSSMIC.2013.6829642].

Position sensitivity in a 3″ × 3″ LaBr3:Ce scintillator

A. Giaz
;
F. Camera
;
S. Riboldi
;
2013

Abstract

The position sensitivity of a cylindrical continuous 3″ × 3″ (7.62 cm × 7.62 cm) LaBr3:Ce crystal was studied using a collimated beam of 662 keV gamma rays and a spectroscopic shielded PMT (HAMAMATSU R6233-100SEL) with standard passive voltage divider (HAMAMATSU E1198-26). The used crystal is sealed in a capsule and has diffusive/reflective surfaces to optimize the energy resolution. A complete scan of the crystal was performed with a 5 mm step grid. The data show that, in average, the image, produced by the scintillation light on the photocathode, changes with the source position. By using the measured full energy peak position using three different windows on the PMT it was possible to identify the position of the interaction of the incident gamma ray.
No
English
Radiation; Nuclear and High Energy Physics; Radiology, Nuclear Medicine and Imaging
Settore FIS/04 - Fisica Nucleare e Subnucleare
Intervento a convegno
Ricerca di base
Pubblicazione scientifica
IEEE Nuclear Science Symposium Conference Record
Institute of Electrical and Electronics Engineers Inc.
2013
1
3
3
9781479905348
Volume a diffusione internazionale
2013 60th IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2013
Seoul, kor
2013
and Electronics Engineers (IEEE NPSS)
Society of the Institute of Electrical
The Nuclear and Plasma Sciences
Convegno internazionale
Intervento inviato
scopus
crossref
Aderisco
A. Giaz, F. Camera, N. Blasi, C. Boiano, S. Brambilla, S. Coelli, B. Million, S. Riboldi, O. Wieland
Book Part (author)
none
273
Position sensitivity in a 3″ × 3″ LaBr3:Ce scintillator / A. Giaz, F. Camera, N. Blasi, C. Boiano, S. Brambilla, S. Coelli, B. Million, S. Riboldi, O. Wieland - In: IEEE Nuclear Science Symposium Conference Record[s.l] : Institute of Electrical and Electronics Engineers Inc., 2013. - ISBN 9781479905348. - pp. 1-3 (( convegno 2013 60th IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2013 tenutosi a Seoul, kor nel 2013 [10.1109/NSSMIC.2013.6829642].
info:eu-repo/semantics/bookPart
9
Prodotti della ricerca::03 - Contributo in volume
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/248404
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact