In many in-beam gamma spectroscopy experiments the detection of high-energy gamma rays in the range up to 10-20 MeV is of primary importance. New generation high-resolution gamma-ray spectrometers like AGATA and GRETA are composed of position sensitive segmented HPGe detectors and provide a reconstruction of the gamma-ray tracks. The performance of AGATA detectors in this energy range has, however, never been studied in detail. A measurement of the response to 15.1 MeV gamma rays has been performed using two HPGe triple clusters of the AGATA Demonstrator array, operating at LNL-INFN. This manuscript presents the preliminary results of a test of the AGATA detectors for the measurement of high-energy gamma rays, in terms of detection efficiency, energy resolution, tracking and performance of the pulse shape analysis (PSA) algorithms.

Response of AGATA segmented HPGe detectors to gamma-rays up to 15.1 MeV / F.C.L. Crespi, R. Avigo, F. Camera, G. Benzoni, N. Blasi, S. Bottoni, A. Bracco, S. Brambilla, P. Casati, F. Coniglio, A. Corsi, A. Giaz, S. Leoni, B. Million, R. Nicolini, L. Pellegri, S. Riboldi, V. Vandone, O. Wieland, S. Akkoyun, A. Atac, D. Bazzacco, M. Bellato, D. Bortolato, E. Calore, M. Ciemala, E. Farnea, A. Gadea, A. Gottardo, M. Kmiecik, A. Maj, D. Mengoni, C. Michelagnoli, D. Montanari, D.R. Napoli, J. Nyberg, F. Recchia, E. Sahin, P.-. Söderström, C. Ur, J.J. Valiente Dobon - In: IEEE Nuclear Science Symposium Conference Record[s.l] : IEEE, 2012. - ISBN 9781467301183. - pp. 1147-1149 (( convegno 2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2011 tenutosi a Valencia, esp nel 2011 [10.1109/NSSMIC.2011.6154591].

Response of AGATA segmented HPGe detectors to gamma-rays up to 15.1 MeV

F.C.L. Crespi
Primo
;
R. Avigo;F. Camera;S. Bottoni;A. Bracco;A. Corsi;A. Giaz;S. Leoni;R. Nicolini;L. Pellegri;S. Riboldi;V. Vandone;D. Montanari;
2012

Abstract

In many in-beam gamma spectroscopy experiments the detection of high-energy gamma rays in the range up to 10-20 MeV is of primary importance. New generation high-resolution gamma-ray spectrometers like AGATA and GRETA are composed of position sensitive segmented HPGe detectors and provide a reconstruction of the gamma-ray tracks. The performance of AGATA detectors in this energy range has, however, never been studied in detail. A measurement of the response to 15.1 MeV gamma rays has been performed using two HPGe triple clusters of the AGATA Demonstrator array, operating at LNL-INFN. This manuscript presents the preliminary results of a test of the AGATA detectors for the measurement of high-energy gamma rays, in terms of detection efficiency, energy resolution, tracking and performance of the pulse shape analysis (PSA) algorithms.
English
Radiation; Nuclear and High Energy Physics; Radiology, Nuclear Medicine and Imaging
Settore FIS/04 - Fisica Nucleare e Subnucleare
Intervento a convegno
Ricerca di base
Pubblicazione scientifica
IEEE Nuclear Science Symposium Conference Record
IEEE
2012
1147
1149
3
9781467301183
Volume a diffusione internazionale
2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2011
Valencia, esp
2011
IEEE Nuclear and Plasma Sciences Society (NPSS)
Convegno internazionale
Intervento inviato
scopus
crossref
Aderisco
F.C.L. Crespi, R. Avigo, F. Camera, G. Benzoni, N. Blasi, S. Bottoni, A. Bracco, S. Brambilla, P. Casati, F. Coniglio, A. Corsi, A. Giaz, S. Leoni, B....espandi
Book Part (author)
none
273
Response of AGATA segmented HPGe detectors to gamma-rays up to 15.1 MeV / F.C.L. Crespi, R. Avigo, F. Camera, G. Benzoni, N. Blasi, S. Bottoni, A. Bracco, S. Brambilla, P. Casati, F. Coniglio, A. Corsi, A. Giaz, S. Leoni, B. Million, R. Nicolini, L. Pellegri, S. Riboldi, V. Vandone, O. Wieland, S. Akkoyun, A. Atac, D. Bazzacco, M. Bellato, D. Bortolato, E. Calore, M. Ciemala, E. Farnea, A. Gadea, A. Gottardo, M. Kmiecik, A. Maj, D. Mengoni, C. Michelagnoli, D. Montanari, D.R. Napoli, J. Nyberg, F. Recchia, E. Sahin, P.-. Söderström, C. Ur, J.J. Valiente Dobon - In: IEEE Nuclear Science Symposium Conference Record[s.l] : IEEE, 2012. - ISBN 9781467301183. - pp. 1147-1149 (( convegno 2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2011 tenutosi a Valencia, esp nel 2011 [10.1109/NSSMIC.2011.6154591].
info:eu-repo/semantics/bookPart
41
Prodotti della ricerca::03 - Contributo in volume
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/248383
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
  • OpenAlex ND
social impact