The 16-channel module (BaFPro) that we have originally developed for processing signals of Barium Fluoride scintillators has been recently adopted to made a pulse shape analysis with signals of Lanthanum Bromide scintillators. Our idea is to use the precision of the fast analog stretcher circuit present in the BaFPro module, to capture in precise way the amplitude peak of the LaBr 3 signals. Since in the peak area are concentrate the difference from alfa particle and gamma rays signal shape this type of analysis evidence a clear separation between these two kind of radiation. We report the scatter plot, peak amplitude (Fast) versus total energy (Slow) of the internal activity of LaBr 3 made with our stretcher circuit. © 2010 IEEE.

Pulse shape results of LaBr3 and BaF2 scintillator obtained with a 16 ch. fast analog stretcher module / C. Boiano, F. Camera, S. Brambilla, F. Crespi, S. Frega, S. Riboldi, A. Giaz - In: IEEE Nuclear Science Symposium Conference Record[s.l] : IEEE, 2010. - ISBN 9781424491063. - pp. 268-270 (( convegno 2010 IEEE Nuclear Science Symposium, Medical Imaging Conference, NSS/MIC 2010 and 17th International Workshop on Room-Temperature Semiconductor X-ray and Gamma-ray Detectors, RTSD 2010 tenutosi a Knoxville, TN, usa nel 2010 [10.1109/NSSMIC.2010.5873761].

Pulse shape results of LaBr3 and BaF2 scintillator obtained with a 16 ch. fast analog stretcher module

F. Camera
;
F. Crespi
;
S. Riboldi
;
A. Giaz
2010

Abstract

The 16-channel module (BaFPro) that we have originally developed for processing signals of Barium Fluoride scintillators has been recently adopted to made a pulse shape analysis with signals of Lanthanum Bromide scintillators. Our idea is to use the precision of the fast analog stretcher circuit present in the BaFPro module, to capture in precise way the amplitude peak of the LaBr 3 signals. Since in the peak area are concentrate the difference from alfa particle and gamma rays signal shape this type of analysis evidence a clear separation between these two kind of radiation. We report the scatter plot, peak amplitude (Fast) versus total energy (Slow) of the internal activity of LaBr 3 made with our stretcher circuit. © 2010 IEEE.
No
English
Radiation; Nuclear and High Energy Physics; Radiology, Nuclear Medicine and Imaging
Settore FIS/04 - Fisica Nucleare e Subnucleare
Intervento a convegno
Pubblicazione scientifica
IEEE Nuclear Science Symposium Conference Record
IEEE
2010
268
270
3
9781424491063
Volume a diffusione internazionale
2010 IEEE Nuclear Science Symposium, Medical Imaging Conference, NSS/MIC 2010 and 17th International Workshop on Room-Temperature Semiconductor X-ray and Gamma-ray Detectors, RTSD 2010
Knoxville, TN, usa
2010
Nucl. Plasma Sci. Soc. Inst. Electr. Electron. Eng. (NPSS)
Convegno internazionale
Intervento inviato
scopus
crossref
Aderisco
C. Boiano, F. Camera, S. Brambilla, F. Crespi, S. Frega, S. Riboldi, A. Giaz
Book Part (author)
none
273
Pulse shape results of LaBr3 and BaF2 scintillator obtained with a 16 ch. fast analog stretcher module / C. Boiano, F. Camera, S. Brambilla, F. Crespi, S. Frega, S. Riboldi, A. Giaz - In: IEEE Nuclear Science Symposium Conference Record[s.l] : IEEE, 2010. - ISBN 9781424491063. - pp. 268-270 (( convegno 2010 IEEE Nuclear Science Symposium, Medical Imaging Conference, NSS/MIC 2010 and 17th International Workshop on Room-Temperature Semiconductor X-ray and Gamma-ray Detectors, RTSD 2010 tenutosi a Knoxville, TN, usa nel 2010 [10.1109/NSSMIC.2010.5873761].
info:eu-repo/semantics/bookPart
7
Prodotti della ricerca::03 - Contributo in volume
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/248374
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 5
social impact