Volume and protein concentration of pleural liquid in anesthetized rabbits after 1 or 3 h of mechanical ventilation, with alveolar pressure equal to atmospheric at end expiration, were compared to those occurring after spontaneous breathing. Moreover, coefficient of kinetic friction between samples of visceral and parietal pleura, obtained after spontaneous or mechanical ventilation, sliding in vitro at physiological velocity under physiological load, was determined. Volume of pleural liquid after mechanical ventilation was similar to that previously found during spontaneous ventilation. This finding is contrary to expectation of Moriondo et al. (2005), based on measurement of lymphatic and interstitial pressure. Protein concentration of pleural liquid after mechanical ventilation was also similar to that occurring after spontaneous ventilation. Coefficient of kinetic friction after mechanical ventilation was 0.023 ± 0.001, similar to that obtained after spontaneous breathing.

Pleural liquid and kinetic friction coefficient of mesothelium after mechanical ventilation / F. Bodega, C. Sironi, C. Porta, L. Zocchi, E. Agostoni. - In: RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY. - ISSN 1569-9048. - 206:1-3(2015 Jan), pp. 1-3. [10.1016/j.resp.2014.11.002]

Pleural liquid and kinetic friction coefficient of mesothelium after mechanical ventilation

F. Bodega
Primo
;
C. Sironi
Secondo
;
C. Porta;L. Zocchi
Penultimo
;
E. Agostoni
2015

Abstract

Volume and protein concentration of pleural liquid in anesthetized rabbits after 1 or 3 h of mechanical ventilation, with alveolar pressure equal to atmospheric at end expiration, were compared to those occurring after spontaneous breathing. Moreover, coefficient of kinetic friction between samples of visceral and parietal pleura, obtained after spontaneous or mechanical ventilation, sliding in vitro at physiological velocity under physiological load, was determined. Volume of pleural liquid after mechanical ventilation was similar to that previously found during spontaneous ventilation. This finding is contrary to expectation of Moriondo et al. (2005), based on measurement of lymphatic and interstitial pressure. Protein concentration of pleural liquid after mechanical ventilation was also similar to that occurring after spontaneous ventilation. Coefficient of kinetic friction after mechanical ventilation was 0.023 ± 0.001, similar to that obtained after spontaneous breathing.
Friction coefficient; Mechanical ventilation; Pleural liquid; Pleural mesothelium; Rabbit; Spontaneous breathing
Settore BIO/09 - Fisiologia
gen-2015
7-nov-2014
Article (author)
File in questo prodotto:
File Dimensione Formato  
Pleural-liquid-and-kinetic-friction-coefficient-of-mesothelium-after-mechanical-ventilation_2015_Respiratory-Physiology-Neurobiology.pdf

accesso riservato

Descrizione: pdf articolo
Tipologia: Contratto con l'editore
Dimensione 210.15 kB
Formato Adobe PDF
210.15 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/245942
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact