Objectives. The aim is to evaluate the survival and success rates, as well as the marginal bone loss (MBL) and periodontal indexes of zirconia implants positioned in the esthetic jaw areas. Materials and Method. 13 patients were selected and 20 one-piece zirconia implants were used for the rehabilitation of single tooth or partially edentulous ridge in the esthetic jaw areas. Six months after surgery and then once a year, a clinical-radiographic evaluation was performed in order to estimate peri-implant tissue health and marginal bone loss. Results. The survival and success rates were 100%. The average marginal bone loss from baseline to 48 months after surgery was +2.1mm. Four years after surgery, the median and the mode for visible Plaque Index and Bleeding On Probing resulted 1 whereas Probing Pocket Depth amounted to 3 mm (SD = ± 0.49mm). Conclusion. One-piece zirconia dental implants are characterized by high biocompatibility, low plaque adhesion, and absence of microgap that can be related to the clinical success of these implants even in the esthetic areas.

Zirconia implants in esthetic areas : 4-year follow-up evaluation study / A.E. Borgonovo, R. Censi, V. Vavassori, O. Arnaboldi, C. Maiorana, D. Re. - In: INTERNATIONAL JOURNAL OF DENTISTRY. - ISSN 1687-8728. - 2015(2015), pp. 415029.1-415029.8. [10.1155/2015/415029]

Zirconia implants in esthetic areas : 4-year follow-up evaluation study

A.E. Borgonovo
Primo
;
C. Maiorana
Penultimo
;
D. Re
Ultimo
2015

Abstract

Objectives. The aim is to evaluate the survival and success rates, as well as the marginal bone loss (MBL) and periodontal indexes of zirconia implants positioned in the esthetic jaw areas. Materials and Method. 13 patients were selected and 20 one-piece zirconia implants were used for the rehabilitation of single tooth or partially edentulous ridge in the esthetic jaw areas. Six months after surgery and then once a year, a clinical-radiographic evaluation was performed in order to estimate peri-implant tissue health and marginal bone loss. Results. The survival and success rates were 100%. The average marginal bone loss from baseline to 48 months after surgery was +2.1mm. Four years after surgery, the median and the mode for visible Plaque Index and Bleeding On Probing resulted 1 whereas Probing Pocket Depth amounted to 3 mm (SD = ± 0.49mm). Conclusion. One-piece zirconia dental implants are characterized by high biocompatibility, low plaque adhesion, and absence of microgap that can be related to the clinical success of these implants even in the esthetic areas.
zirconia
Settore MED/28 - Malattie Odontostomatologiche
2015
2014
Article (author)
File in questo prodotto:
File Dimensione Formato  
415029.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 2.75 MB
Formato Adobe PDF
2.75 MB Adobe PDF Visualizza/Apri
415029.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 2.69 MB
Formato Adobe PDF
2.69 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/245483
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 26
  • ???jsp.display-item.citation.isi??? 31
social impact