We compared the accuracy of 2 GPS systems with different sampling rates for the determination of distances covered at high-speed and metabolic power derived from a combination of running speed and acceleration. 8 participants performed 56 bouts of shuttle intermittent running wearing 2 portable GPS devices (SPI-Pro, GPS-5 Hz and MinimaxX, GPS-10 Hz). The GPS systems were compared with a radar system as a criterion measure. The variables investigated were: total distance (TD), high-speed distance (HSR>4.17 m·s-1), very high-speed distance (VHSR>5.56 m·s-1), mean power (Pmean), high metabolic power (HMP>20 W·kg-1) and very high metabolic power (VHMP>25 W·kg-1). GPS-5 Hz had low error for TD (2.8%) and Pmean (4.5%), while the errors for the other variables ranged from moderate to high (7.5-23.2%). GPS-10 Hz demonstrated a low error for TD (1.9%), HSR (4.7%), Pmean (2.4%) and HMP (4.5%), whereas the errors for VHSR (10.5%) and VHMP (6.2%) were moderate. In general, GPS accuracy increased with a higher sampling rate, but decreased with increasing speed of movement. Both systems could be used for calculating TD and Pmean, but they cannot be used interchangeably. Only GPS-10 Hz demonstrated a sufficient level of accuracy for quantifying distance covered at higher speeds or time spent at very high power.

Accuracy of GPS devices for measuring high-intensity running in field-based team sports / E. Rampinini, G. Alberti, M. Fiorenza, M. Riggio, R. Sassi, T.O. Borges, A.J. Coutts. - In: INTERNATIONAL JOURNAL OF SPORTS MEDICINE. - ISSN 0172-4622. - 36:1(2015), pp. 49-53. [10.1055/s-0034-1385866]

Accuracy of GPS devices for measuring high-intensity running in field-based team sports

E. Rampinini;G. Alberti;
2015

Abstract

We compared the accuracy of 2 GPS systems with different sampling rates for the determination of distances covered at high-speed and metabolic power derived from a combination of running speed and acceleration. 8 participants performed 56 bouts of shuttle intermittent running wearing 2 portable GPS devices (SPI-Pro, GPS-5 Hz and MinimaxX, GPS-10 Hz). The GPS systems were compared with a radar system as a criterion measure. The variables investigated were: total distance (TD), high-speed distance (HSR>4.17 m·s-1), very high-speed distance (VHSR>5.56 m·s-1), mean power (Pmean), high metabolic power (HMP>20 W·kg-1) and very high metabolic power (VHMP>25 W·kg-1). GPS-5 Hz had low error for TD (2.8%) and Pmean (4.5%), while the errors for the other variables ranged from moderate to high (7.5-23.2%). GPS-10 Hz demonstrated a low error for TD (1.9%), HSR (4.7%), Pmean (2.4%) and HMP (4.5%), whereas the errors for VHSR (10.5%) and VHMP (6.2%) were moderate. In general, GPS accuracy increased with a higher sampling rate, but decreased with increasing speed of movement. Both systems could be used for calculating TD and Pmean, but they cannot be used interchangeably. Only GPS-10 Hz demonstrated a sufficient level of accuracy for quantifying distance covered at higher speeds or time spent at very high power.
Settore M-EDF/02 - Metodi e Didattiche delle Attivita' Sportive
2015
Article (author)
File in questo prodotto:
File Dimensione Formato  
Rampinini E et al_2014_Int J Sports Med_Accuracy of GPS Devices for Measuring High-intensity.pdf

Open Access dal 07/11/2015

Tipologia: Publisher's version/PDF
Dimensione 298.04 kB
Formato Adobe PDF
298.04 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/242805
Citazioni
  • ???jsp.display-item.citation.pmc??? 58
  • Scopus 199
  • ???jsp.display-item.citation.isi??? 180
social impact