The discrimination among atrial rhythms is obtained through the analysis of linear and non-linear dynamics of atria electrograms and local atrial period (LAP) series. Linear and non-linear degree of coupling between atrial electrograms have been assessed using cross-correlation (CCI) and synchronization indexes. Dynamics of LAP series were investigated using level of predictability (LP) and regularity indexes. Atrial fibrillation (AF) episodes, classified according to Wells' criteria, were investigated. We found that metrics obtained from LAP series provide the best performance in the classification of AF rhythms. The LP index misclassified only 12 AF episodes over 87. Synchronization index was the most performing metric in the discrimination between organized and not-organized fibrillation: detection of organized rhythm; sensitivity (SE) > 95%; positive predictability (+P) > 95%. LP (SE: 89%; +P: 89%) and CCI (SE: 87%; +P: 83%) provide slightly lower performances.

Discrimination of atrial rhythms by linear and non-linear methods / L.T. Mainardi, A. Porta, G. Calcagnini, F. Censi, P. Bartolini, A. Michelucci, S. Cerutti. - In: ANNALI DELL'ISTITUTO SUPERIORE DI SANITÀ. - ISSN 0021-2571. - 37:3(2001), pp. 335-340.

Discrimination of atrial rhythms by linear and non-linear methods

A. Porta
Secondo
;
2001

Abstract

The discrimination among atrial rhythms is obtained through the analysis of linear and non-linear dynamics of atria electrograms and local atrial period (LAP) series. Linear and non-linear degree of coupling between atrial electrograms have been assessed using cross-correlation (CCI) and synchronization indexes. Dynamics of LAP series were investigated using level of predictability (LP) and regularity indexes. Atrial fibrillation (AF) episodes, classified according to Wells' criteria, were investigated. We found that metrics obtained from LAP series provide the best performance in the classification of AF rhythms. The LP index misclassified only 12 AF episodes over 87. Synchronization index was the most performing metric in the discrimination between organized and not-organized fibrillation: detection of organized rhythm; sensitivity (SE) > 95%; positive predictability (+P) > 95%. LP (SE: 89%; +P: 89%) and CCI (SE: 87%; +P: 83%) provide slightly lower performances.
Atrial signal; Linear predictability; Non-linear dynamics; Regularity; Synchronization
Settore ING-INF/06 - Bioingegneria Elettronica e Informatica
2001
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/24088
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 5
  • ???jsp.display-item.citation.isi??? ND
social impact