In this paper, a detailed study on the possibility and significance of performing a parametric estimation of sample entropy (SampEn) is proposed. SampEn is a non-linear metric, meant to quantify regularity of a time series. It is widely employed on biomedical signals, especially on heart rate variability. Results relevant to approximate entropy, a related index, are also reported. An analytical expression for SampEn of an autoregressive (AR) model is derived first. Then we study the feasibility of a parametric estimation of SampEn through AR models, both on synthetic and real series. RR series of different lengths are fitted to an AR model and then expected values of SampEn (SampEnμ) are estimated. Values of SampEn, computed from real beat-to-beat interval time series (obtained from 72 normal subjects and 29 congestive heart failure patients), with m = 1 and r = 0.2, are within the standard range of SampEnμ more than 83% (for series length N = 75) and 28% (for N = 1500) of the cases. Surrogate data have been employed to verify if departures from Gaussianity are to account for the mismatch. The work supports the finding that when numerical and parametric estimates of SampEn agree, SampEn is mainly influenced by linear properties of the series. A disagreement, on the contrary, might point those cases where SampEn is truly offering new information, not readily available with traditional temporal and spectral parameters.

Parametric estimation of sample entropy in heart rate variability analysis / M. Aktaruzzaman, R. Sassi. - In: BIOMEDICAL SIGNAL PROCESSING AND CONTROL. - ISSN 1746-8094. - 14:1(2014), pp. 141-147. [10.1016/j.bspc.2014.07.011]

Parametric estimation of sample entropy in heart rate variability analysis

M. Aktaruzzaman
Primo
;
R. Sassi
2014

Abstract

In this paper, a detailed study on the possibility and significance of performing a parametric estimation of sample entropy (SampEn) is proposed. SampEn is a non-linear metric, meant to quantify regularity of a time series. It is widely employed on biomedical signals, especially on heart rate variability. Results relevant to approximate entropy, a related index, are also reported. An analytical expression for SampEn of an autoregressive (AR) model is derived first. Then we study the feasibility of a parametric estimation of SampEn through AR models, both on synthetic and real series. RR series of different lengths are fitted to an AR model and then expected values of SampEn (SampEnμ) are estimated. Values of SampEn, computed from real beat-to-beat interval time series (obtained from 72 normal subjects and 29 congestive heart failure patients), with m = 1 and r = 0.2, are within the standard range of SampEnμ more than 83% (for series length N = 75) and 28% (for N = 1500) of the cases. Surrogate data have been employed to verify if departures from Gaussianity are to account for the mismatch. The work supports the finding that when numerical and parametric estimates of SampEn agree, SampEn is mainly influenced by linear properties of the series. A disagreement, on the contrary, might point those cases where SampEn is truly offering new information, not readily available with traditional temporal and spectral parameters.
Autoregressive models; Heart rate variability; Parametric estimates; Sample entropy
Settore INF/01 - Informatica
Settore ING-INF/06 - Bioingegneria Elettronica e Informatica
2014
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/239679
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 51
  • ???jsp.display-item.citation.isi??? 43
social impact