Background: The potential requirement for hardware removal originally fueled the development of bioabsorbable pins as an alternative to metal screws for fixing osteotomy sites in foot surgery. More recently, the concern regarding the adverse effects of metal implants may provide further grounds for using bioabsorbable rather than metal fixation. Methods: This is a prospective study of 383 consecutive patients (439 feet) who underwent a chevron osteotomy to correct a hallux valgus deformity performed between 2005 and 2010. In the study group of 251 patients (285 feet), the distal metatarsal osteotomy was fixed with a bioabsorbable pin made of poly-L-lactide and poly-DL-lactide (70:30 ratio). In the control group of 132 patients (154 feet), the osteotomy was fixed with a metal screw. The average follow-up was 27 months for the study group and 31 months for the control group. Results: We observed statistically significant improvements in the mean intermetatarsal angle of 6.1 ± 2.7 degrees in the study group and 5.2 ± 1.6 degrees in the control group (P < .001) and in the mean hallux valgus angle of 14.8 ± 4.7 degrees and 15.5 ± 3.7 degrees, respectively (P < .001). The mean ± SD improvement on the American Orthopaedic Foot and Ankle Society 100-point scale was 45 ± 11 points for the study group and 49 ± 15 points for the control (P < .001). Our complication rate was 0.7% for the study group. Conclusion: Our study found that fixation with a bioabsorbable pin was as reliable as fixation with a metal screw and allowed major angular corrections. The bioabsorbable polymer was well tolerated, and the complication rate was low.

Chevron Osteotomy of the First Metatarsal Stabilized With an Absorbable Pin : Our 5-year Experience / A. Morandi, E. Ungaro, A. Fraccia, V. Sansone. - In: FOOT & ANKLE INTERNATIONAL. - ISSN 1071-1007. - 34:3(2013), pp. 380-385.

Chevron Osteotomy of the First Metatarsal Stabilized With an Absorbable Pin : Our 5-year Experience

V. Sansone
Ultimo
2013

Abstract

Background: The potential requirement for hardware removal originally fueled the development of bioabsorbable pins as an alternative to metal screws for fixing osteotomy sites in foot surgery. More recently, the concern regarding the adverse effects of metal implants may provide further grounds for using bioabsorbable rather than metal fixation. Methods: This is a prospective study of 383 consecutive patients (439 feet) who underwent a chevron osteotomy to correct a hallux valgus deformity performed between 2005 and 2010. In the study group of 251 patients (285 feet), the distal metatarsal osteotomy was fixed with a bioabsorbable pin made of poly-L-lactide and poly-DL-lactide (70:30 ratio). In the control group of 132 patients (154 feet), the osteotomy was fixed with a metal screw. The average follow-up was 27 months for the study group and 31 months for the control group. Results: We observed statistically significant improvements in the mean intermetatarsal angle of 6.1 ± 2.7 degrees in the study group and 5.2 ± 1.6 degrees in the control group (P < .001) and in the mean hallux valgus angle of 14.8 ± 4.7 degrees and 15.5 ± 3.7 degrees, respectively (P < .001). The mean ± SD improvement on the American Orthopaedic Foot and Ankle Society 100-point scale was 45 ± 11 points for the study group and 49 ± 15 points for the control (P < .001). Our complication rate was 0.7% for the study group. Conclusion: Our study found that fixation with a bioabsorbable pin was as reliable as fixation with a metal screw and allowed major angular corrections. The bioabsorbable polymer was well tolerated, and the complication rate was low.
No
English
hallux valgus ; chevron osteotomy ; Austin osteotomy ; absorbable pin
Settore MED/33 - Malattie Apparato Locomotore
Articolo
Esperti anonimi
Ricerca applicata
Pubblicazione scientifica
2013
34
3
380
385
6
Pubblicato
Periodico con rilevanza internazionale
info:eu-repo/semantics/article
Chevron Osteotomy of the First Metatarsal Stabilized With an Absorbable Pin : Our 5-year Experience / A. Morandi, E. Ungaro, A. Fraccia, V. Sansone. - In: FOOT & ANKLE INTERNATIONAL. - ISSN 1071-1007. - 34:3(2013), pp. 380-385.
reserved
Prodotti della ricerca::01 - Articolo su periodico
4
262
Article (author)
si
A. Morandi, E. Ungaro, A. Fraccia, V. Sansone
File in questo prodotto:
File Dimensione Formato  
Chevron osteotomy of the first metatarsal stabilized with an absorbable pin.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 298.73 kB
Formato Adobe PDF
298.73 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/236944
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 10
social impact