Aims: The purpose of this study was to evaluate the effects of Global Proprioceptive Resonance (GPR) by Multifocal Vibrations (MFV) on muscle activity of the stomatognatic system in healthy subjects. The aim was to find out a correlation between the neuromuscular system (electromyography) and an ergonomic structure. Materials and Methods: Fifteen volunteers (7 males and 8 females, aged 19-25 years) underwent the electromyography exam before the multi focal vibration and immediately after it, 4 times a month on regular pauses. The group was evaluated at time T0 (I week), T1 (II week), T2 (III week), T3 (IV week). The volunteers had some common features: I molar and canine class, facial symmetry, no temporomandibular joint (TMJ) diseases. Keope is the ergonomic structure used in this protocol. K6-Myotronics EMG-EKG has been used in this study. Results: Results showed a change in the neuromuscular activity in each single exam, after MFV both in the muscular electrical activity at rest (SCAN 9) and in the freeway space (SCAN 3). This change however doesn’t remain from one session to another: the neuromuscular system is too much susceptible to external factors (physical activity, weariness, emotions ecc.) to keep the changes obtained thanks to Keope. Conclusions: In this study it is clear that GPR induced changes in neuromuscular system, although these changes aren’t stable.

Scopi del lavoro: Lo scopo di questo studio è stato valutare gli effetti della Risonanza Propriocettiva Globale (GPR) a Vibrazione Multifocale (MFV) sulla attività muscolare dell’apparato stomatognatico in soggetti sani, ed individuare una correlazione tra il sistema neuromuscolare (elettromiografia) ed una struttura ergonomica (Keope) che induce rilassamento neuromuscolare. Materiali e Metodi: Quindici volontari (7 maschi e 8 femmine tra 19 e 25 anni) sono stati sottoposti all’esame elettromiografico prima e subito dopo MFV per 4 sedute ad intervalli regolari nell’arco di un mese. Il gruppo è stato indagato al tempo T0 (I settimana), T1 (II settimana), T2 (III settimana), T3 (IV settimana). Keope è la struttura ergonomica utilizzata in questo protocollo. L’elettromiografo di riferimento è EMG-K6 Myotronics. Risultati:I risultati hanno mostrato un cambiamento dell'attività neuromuscolare nell’arco di ogni singola seduta, dopo MFV, in termini di attività elettrica muscolare a riposo (SCAN 9) e freeway-space (SCAN 3). Tale cambiamento tuttavia non si mantiene tra una seduta e la successiva: si ritiene che il sistema neuromuscolare sia troppo suscettibile a fattori esterni (attività fisica, affaticamento, stato emotivo…) per conservare stabilmente gli effetti apportati da Keope. Conclusioni:In questo studio si evidenzia che GPR induce modifiche nel sistema neuromuscolare, sebbene tali cambiamenti non siano predicibili e stabili nel tempo.

Global Proprioceptive Resonance : long-terms results on neuromuscular system - Risonanza Propriocettiva Globale : risultati sul sistema neuromuscolare / U. Garagiola, L. Terzi, P. Cressoni. ((Intervento presentato al 44. convegno Sido International Congress tenutosi a Roma nel 2013.

Global Proprioceptive Resonance : long-terms results on neuromuscular system - Risonanza Propriocettiva Globale : risultati sul sistema neuromuscolare

U. Garagiola;
2013

Abstract

Aims: The purpose of this study was to evaluate the effects of Global Proprioceptive Resonance (GPR) by Multifocal Vibrations (MFV) on muscle activity of the stomatognatic system in healthy subjects. The aim was to find out a correlation between the neuromuscular system (electromyography) and an ergonomic structure. Materials and Methods: Fifteen volunteers (7 males and 8 females, aged 19-25 years) underwent the electromyography exam before the multi focal vibration and immediately after it, 4 times a month on regular pauses. The group was evaluated at time T0 (I week), T1 (II week), T2 (III week), T3 (IV week). The volunteers had some common features: I molar and canine class, facial symmetry, no temporomandibular joint (TMJ) diseases. Keope is the ergonomic structure used in this protocol. K6-Myotronics EMG-EKG has been used in this study. Results: Results showed a change in the neuromuscular activity in each single exam, after MFV both in the muscular electrical activity at rest (SCAN 9) and in the freeway space (SCAN 3). This change however doesn’t remain from one session to another: the neuromuscular system is too much susceptible to external factors (physical activity, weariness, emotions ecc.) to keep the changes obtained thanks to Keope. Conclusions: In this study it is clear that GPR induced changes in neuromuscular system, although these changes aren’t stable.
2013
Scopi del lavoro: Lo scopo di questo studio è stato valutare gli effetti della Risonanza Propriocettiva Globale (GPR) a Vibrazione Multifocale (MFV) sulla attività muscolare dell’apparato stomatognatico in soggetti sani, ed individuare una correlazione tra il sistema neuromuscolare (elettromiografia) ed una struttura ergonomica (Keope) che induce rilassamento neuromuscolare. Materiali e Metodi: Quindici volontari (7 maschi e 8 femmine tra 19 e 25 anni) sono stati sottoposti all’esame elettromiografico prima e subito dopo MFV per 4 sedute ad intervalli regolari nell’arco di un mese. Il gruppo è stato indagato al tempo T0 (I settimana), T1 (II settimana), T2 (III settimana), T3 (IV settimana). Keope è la struttura ergonomica utilizzata in questo protocollo. L’elettromiografo di riferimento è EMG-K6 Myotronics. Risultati:I risultati hanno mostrato un cambiamento dell'attività neuromuscolare nell’arco di ogni singola seduta, dopo MFV, in termini di attività elettrica muscolare a riposo (SCAN 9) e freeway-space (SCAN 3). Tale cambiamento tuttavia non si mantiene tra una seduta e la successiva: si ritiene che il sistema neuromuscolare sia troppo suscettibile a fattori esterni (attività fisica, affaticamento, stato emotivo…) per conservare stabilmente gli effetti apportati da Keope. Conclusioni:In questo studio si evidenzia che GPR induce modifiche nel sistema neuromuscolare, sebbene tali cambiamenti non siano predicibili e stabili nel tempo.
Settore MED/28 - Malattie Odontostomatologiche
Global Proprioceptive Resonance : long-terms results on neuromuscular system - Risonanza Propriocettiva Globale : risultati sul sistema neuromuscolare / U. Garagiola, L. Terzi, P. Cressoni. ((Intervento presentato al 44. convegno Sido International Congress tenutosi a Roma nel 2013.
Conference Object
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/233984
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact