The EXPADES (EXotic PArticle DEtection System) detector array consists of 16 Double Side Silicon Strip Detectors (DSSSD) with active areas of 64 × 64 mm2, arranged in 8 ΔE (40/50 μm)–E (300 μm) telescopes. All detector faces are segmented into 32 × 2-mm wide strips, ensuring a 2 × 2 mm2 pixel configuration. Eight ionization chambers can be alternatively used as ΔE stages or, if needed, as an additional third layer for more complex triple telescopes. The signals from silicon ΔE layers and from ionization chambers are read by standard electronics, while innovative 32-channel ASIC chips are employed for the readout of the E stages. The results of off-line tests with alpha sources and from the first in-beam experiment with a 17O beam are presented.

The high granularity and large solid angle detection array EXPADES / E. Strano, A. Anastasio, M. Bettini, A. Boiano, C. Boiano, C. Cassese, L. Castellani, D. Corti, P. Di Meo, G. Galet, T. Glodariu, J. Grebosz, A. Guglielmetti, M. La Commara, C. Manea, M. Mazzocco, P. Molini, M. Nicoletto, C. Parascandolo, L. Parascandolo, D. Pierroutsakou, G. Pontoriere, L. Roscilli, C. Signorini, F. Soramel, L. Stroe, M. Tessaro, N. Toniolo, D. Torresi, P. Zatti. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION B, BEAM INTERACTIONS WITH MATERIALS AND ATOMS. - ISSN 0168-583X. - 317(2013), pp. 657-660. [10.1016/j.nimb.2013.06.035]

The high granularity and large solid angle detection array EXPADES

A. Guglielmetti;
2013

Abstract

The EXPADES (EXotic PArticle DEtection System) detector array consists of 16 Double Side Silicon Strip Detectors (DSSSD) with active areas of 64 × 64 mm2, arranged in 8 ΔE (40/50 μm)–E (300 μm) telescopes. All detector faces are segmented into 32 × 2-mm wide strips, ensuring a 2 × 2 mm2 pixel configuration. Eight ionization chambers can be alternatively used as ΔE stages or, if needed, as an additional third layer for more complex triple telescopes. The signals from silicon ΔE layers and from ionization chambers are read by standard electronics, while innovative 32-channel ASIC chips are employed for the readout of the E stages. The results of off-line tests with alpha sources and from the first in-beam experiment with a 17O beam are presented.
ASIC electronics; High-granularity silicon detectors; Ionization chambers; Radioactive Ion Beams
Settore FIS/04 - Fisica Nucleare e Subnucleare
2013
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/229370
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 25
  • ???jsp.display-item.citation.isi??? 25
social impact