The aim of this study was to enhance the ECG pre-processing modalities for beat-to-beat QT interval variability measurement based on template matching. The R-peak detection algorithm has been substituted and an efficient baseline removal algorithm has been implemented in existing computer software. To test performance we used simulated ECG data with fixed QT intervals featuring Gaussian noise, baseline wander and amplitude modulation and two alternative algorithms. We computed the standard deviation of beat-to-beat QT intervals as a marker of QT interval variability (QTV). Significantly a lower beat-to-beat QTV was found in the updated approach compared the original algorithm. In addition, the updated template matching computer software outperformed the previous version in discarding fewer beats. In conclusion, the updated ECG preprocessing algorithm is recommended for more accurate quantification of beat-to-beat QT interval variability.

Improved ECG pre-processing for beat-to-beat QT interval variability measurement / M.A. Hasan, V. Starc, A. Porta, D. Abbott, M. Baumert (PROCEEDINGS OF THE ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY). - In: Engineering in Medicine and Biology Society (EMBC), 2013 35th Annual International Conference of the IEEE[s.l] : IEEE Press, 2013. - ISBN 9781457702167. - pp. 2563-2566 (( Intervento presentato al 35. convegno Annual International Conference of the IEEE EMBS tenutosi a Osaka nel 2013 [10.1109/EMBC.2013.6610063].

Improved ECG pre-processing for beat-to-beat QT interval variability measurement

A. Porta;
2013

Abstract

The aim of this study was to enhance the ECG pre-processing modalities for beat-to-beat QT interval variability measurement based on template matching. The R-peak detection algorithm has been substituted and an efficient baseline removal algorithm has been implemented in existing computer software. To test performance we used simulated ECG data with fixed QT intervals featuring Gaussian noise, baseline wander and amplitude modulation and two alternative algorithms. We computed the standard deviation of beat-to-beat QT intervals as a marker of QT interval variability (QTV). Significantly a lower beat-to-beat QTV was found in the updated approach compared the original algorithm. In addition, the updated template matching computer software outperformed the previous version in discarding fewer beats. In conclusion, the updated ECG preprocessing algorithm is recommended for more accurate quantification of beat-to-beat QT interval variability.
Settore ING-INF/06 - Bioingegneria Elettronica e Informatica
2013
Book Part (author)
File in questo prodotto:
File Dimensione Formato  
Hasan_EMBC_2013.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 284.56 kB
Formato Adobe PDF
284.56 kB Adobe PDF   Visualizza/Apri   Richiedi una copia