Aim: To verify which of the various biomarkers of internal dose of benzene can be considered reliable for biological monitoring of exposure to the low concentrations present nowadays in working and living environments. Materials and Methods: The specific literature was analyzed to assess the reliability of the different biomarkers of internal dose. Results and Conclusions: t,t-muconic acid is a non specific biomarker for benzene, valid for exposure to concentrations up to one order of magnitude less than the threshold limit of 3250 μg/m3. S-phenylmercapturic acid (SPMA) is a reliable marker even for exposure to concentrations up to two orders below the threshold value of 3250 μg/m3, and can be considered the biomarker of choice for biological monitoring of workers exposed to benzene. Urinary benzene does not seem to have any real advantages over SPMA for monitoring occupational exposure to benzene, but it does seem to be more reliable than SPMA to assess exposure to concentrations like those present in living environments. A smoking habit influences the urinary excretion of all the described biomarkers, and for the current low levels of occupational and environmental exposure to benzene, must be taken into account when interpreting the results of biological monitoring.

Il monitoraggio dell'esposizione occupazionale ed ambientale a basse dosi di benzene / P. Lovreglio, M. Carrieri, A. Barbieri, L. Sabatini, S. Fustinoni, R. Andreoli, M.N. D'Errico, A. Basso, G.B. Bartolucci, L. Soleo. - In: GIORNALE ITALIANO DI MEDICINA DEL LAVORO ED ERGONOMIA. - ISSN 1592-7830. - 35:4(2013 Oct), pp. 251-255. ((Intervento presentato al 76. convegno nazionale SIMLII : Tutela e promozione della salute : il contributio metodologico della Medina del Lavoro alla valutazione e gestione dei rischi nell'ambiente di vita e di lavoro tenutosi a Giardini Naxos (ME) nel 2013.

Il monitoraggio dell'esposizione occupazionale ed ambientale a basse dosi di benzene

S. Fustinoni;
2013

Abstract

Aim: To verify which of the various biomarkers of internal dose of benzene can be considered reliable for biological monitoring of exposure to the low concentrations present nowadays in working and living environments. Materials and Methods: The specific literature was analyzed to assess the reliability of the different biomarkers of internal dose. Results and Conclusions: t,t-muconic acid is a non specific biomarker for benzene, valid for exposure to concentrations up to one order of magnitude less than the threshold limit of 3250 μg/m3. S-phenylmercapturic acid (SPMA) is a reliable marker even for exposure to concentrations up to two orders below the threshold value of 3250 μg/m3, and can be considered the biomarker of choice for biological monitoring of workers exposed to benzene. Urinary benzene does not seem to have any real advantages over SPMA for monitoring occupational exposure to benzene, but it does seem to be more reliable than SPMA to assess exposure to concentrations like those present in living environments. A smoking habit influences the urinary excretion of all the described biomarkers, and for the current low levels of occupational and environmental exposure to benzene, must be taken into account when interpreting the results of biological monitoring.
Settore MED/44 - Medicina del Lavoro
ott-2013
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/227054
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 11
  • ???jsp.display-item.citation.isi??? ND
  • OpenAlex ND
social impact