An experimental technique is described in the present work capable to identify pileup events and to reconstruct the hidden energy information. The procedure is based on the pulse shape analysis of digitized signals with the help of a high frequency, fast and sensitive flash ADC. The CAEN module V1729A, operating at a maximum sampling rate of 2 GHz has been successfully used in a recent experiment performed at the INFN-LNL EXOTIC facility, Padova, with an incident 8B beam near barrier energies (EL=25-40 MeV) on a three stage Si telescope. The nature of the unstable beam nucleus, which decays in 8Be and consequently in two alphas, necessitates the usage of appropriate pileup rejection techniques. The proposed offline algorithmic approach has efficiently identified all the recorded pileup events and in most cases has successfully reconstructed the energy information of the overlapping signals. Details of the applied technique with energy reconstruction examples for normal and pileup events are discussed in the present work.

Energy reconstruction from PileUp events / E. Stiliaris A. Pakou, D. Pierroutsakou, A. Boiano, C. Boiano, D. Filipescu, T. Glodariu, S. Grebosz, A. Guglielmetti, M. La Commara, M. Mazzocco, C. Parascandolo, K. Rusek, A. M. Sanchez Benitez, C. Signorini, O. Sgouros, F. Soramel, V. Soukeras, E. Strano, L. Stroe, N. Toniolo, D. Torresi, K. Zerva - In: 2012 IEEE Nuclear science symposium and medical imaging conference record (NSS/MIC 2012) / [a cura di] Bo Yu. - Piscataway : IEEE, 2012. - ISBN 978-1-4673-2028-3. - pp. 1092-1097 (( convegno Nuclear science symposium and medical imaging conference tenutosi a Anaheim, California, USA nel 2012 [10.1109/NSSMIC.2012.6551275].

Energy reconstruction from PileUp events

A. Guglielmetti;
2012

Abstract

An experimental technique is described in the present work capable to identify pileup events and to reconstruct the hidden energy information. The procedure is based on the pulse shape analysis of digitized signals with the help of a high frequency, fast and sensitive flash ADC. The CAEN module V1729A, operating at a maximum sampling rate of 2 GHz has been successfully used in a recent experiment performed at the INFN-LNL EXOTIC facility, Padova, with an incident 8B beam near barrier energies (EL=25-40 MeV) on a three stage Si telescope. The nature of the unstable beam nucleus, which decays in 8Be and consequently in two alphas, necessitates the usage of appropriate pileup rejection techniques. The proposed offline algorithmic approach has efficiently identified all the recorded pileup events and in most cases has successfully reconstructed the energy information of the overlapping signals. Details of the applied technique with energy reconstruction examples for normal and pileup events are discussed in the present work.
Settore ING-INF/01 - Elettronica
Settore FIS/04 - Fisica Nucleare e Subnucleare
2012
IEEE
Book Part (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/226521
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact