Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
IRIS Institutional Research Information System - AIR Archivio Istituzionale della Ricerca
The BaBar Silicon Vertex Tracker (SVT) has been efficiently operated for six years since the start of data taking in 1999. Due to higher than expected background levels some unforeseen effects have appeared. We discuss: a shift in the pedestal for the channels of the AToM readout chips that are most exposed to radiation; an anomalous increase in the bias leakage current for the modules in the outer layers. Estimates of future radiation doses and occupancies are shown together with the extrapolated detector performance and lifetime, in light of the new observations.
BABAR silicon vertex tracker: Status and prospects / V. RE, M. BONDIOLI, M. BRUINSMA, S. CURRY, D. KIRKBY, J. BERRYHILL, S. BURKE, D. CALLAHAN, C. CAMPAGNARI, A. CUNHA, B. DAHMES, D. HALE, S. KYRE, J. RICHMAN, J. STONER, W. VERKERKE, T. BECK, A.M. EISNER, J. KROSEBERG, W.S. LOCKMAN, G. NESOM, A. SEIDEN, P. SPRADLIN, M. WILSON, L. WINSTROM, C. BOZZI, G. CIBINETTO, L. PIEMONTESE, D. BROWN, E. CHARLES, S. DARDIN, F. GOOZEN, A. GRITSAN, L.T. KERTH, G. LYNCH, N.A. ROE, C. CHEN, C.K. LAE, D. ROBERTS, G. SIMI, A. LAZZARO, F. PALOMBO, H.L. SNOEK, L. RATTI, C. ANGELINI, G. BATIGNANI, S. BETTARINI, F. BOSI, F. BUCCI, G. CALDERINI, M. CARPINELLI, M. CECCANTI, F. FORTI, R. CENCI, M.A. GIORGI, A. LUSIANI, P. MAMMINI, P.F. MANFREDI, G. MARCHIORI, M. MAZUR, M. MORGANTI, F. MORSANI, N. NERI, E. PAOLONI, A. PROFETI, M. RAMA, G. RIZZO, J. WALSH, P. ELMER, O. LONG, A. PERAZZO, P. BURCHAT, A.J. EDWARDS, S. MAJEWSKI, B.A. PETERSEN, M. BONA, F. BIANCHI, D. GAMBA, P. TRAPANI, M. BOMBEN, L. BOSISIO, C. CARTARO, F. COSSUTTI, G. DELLA RICCA, S. DITTONGO, L. LANCERI, L. VITALE, M. DATTA, A. MIHALYI. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 569:1(2006), pp. 1-4.
BABAR silicon vertex tracker: Status and prospects
V. RE;M. BONDIOLI;M. BRUINSMA;S. CURRY;D. KIRKBY;J. BERRYHILL;S. BURKE;D. CALLAHAN;C. CAMPAGNARI;A. CUNHA;B. DAHMES;D. HALE;S. KYRE;J. RICHMAN;J. STONER;W. VERKERKE;T. BECK;A. M. EISNER;J. KROSEBERG;W. S. LOCKMAN;G. NESOM;A. SEIDEN;P. SPRADLIN;M. WILSON;L. WINSTROM;C. BOZZI;G. CIBINETTO;L. PIEMONTESE;D. BROWN;E. CHARLES;S. DARDIN;F. GOOZEN;A. GRITSAN;L. T. KERTH;G. LYNCH;N. A. ROE;C. CHEN;C. K. LAE;D. ROBERTS;G. SIMI;A. LAZZARO;F. PALOMBO;H. L. SNOEK;L. RATTI;C. ANGELINI;G. BATIGNANI;S. BETTARINI;F. BOSI;F. BUCCI;G. CALDERINI;M. CARPINELLI;M. CECCANTI;F. FORTI;R. CENCI;M. A. GIORGI;A. LUSIANI;P. MAMMINI;P. F. MANFREDI;G. MARCHIORI;M. MAZUR;M. MORGANTI;F. MORSANI;N. NERI;E. PAOLONI;A. PROFETI;M. RAMA;G. RIZZO;J. WALSH;P. ELMER;O. LONG;A. PERAZZO;P. BURCHAT;A. J. EDWARDS;S. MAJEWSKI;B. A. PETERSEN;M. BONA;F. BIANCHI;D. GAMBA;P. TRAPANI;M. BOMBEN;L. BOSISIO;C. CARTARO;F. COSSUTTI;G. DELLA RICCA;S. DITTONGO;L. LANCERI;L. VITALE;M. DATTA;A. MIHALYI
2006
Abstract
The BaBar Silicon Vertex Tracker (SVT) has been efficiently operated for six years since the start of data taking in 1999. Due to higher than expected background levels some unforeseen effects have appeared. We discuss: a shift in the pedestal for the channels of the AToM readout chips that are most exposed to radiation; an anomalous increase in the bias leakage current for the modules in the outer layers. Estimates of future radiation doses and occupancies are shown together with the extrapolated detector performance and lifetime, in light of the new observations.
BABAR silicon vertex tracker: Status and prospects / V. RE, M. BONDIOLI, M. BRUINSMA, S. CURRY, D. KIRKBY, J. BERRYHILL, S. BURKE, D. CALLAHAN, C. CAMPAGNARI, A. CUNHA, B. DAHMES, D. HALE, S. KYRE, J. RICHMAN, J. STONER, W. VERKERKE, T. BECK, A.M. EISNER, J. KROSEBERG, W.S. LOCKMAN, G. NESOM, A. SEIDEN, P. SPRADLIN, M. WILSON, L. WINSTROM, C. BOZZI, G. CIBINETTO, L. PIEMONTESE, D. BROWN, E. CHARLES, S. DARDIN, F. GOOZEN, A. GRITSAN, L.T. KERTH, G. LYNCH, N.A. ROE, C. CHEN, C.K. LAE, D. ROBERTS, G. SIMI, A. LAZZARO, F. PALOMBO, H.L. SNOEK, L. RATTI, C. ANGELINI, G. BATIGNANI, S. BETTARINI, F. BOSI, F. BUCCI, G. CALDERINI, M. CARPINELLI, M. CECCANTI, F. FORTI, R. CENCI, M.A. GIORGI, A. LUSIANI, P. MAMMINI, P.F. MANFREDI, G. MARCHIORI, M. MAZUR, M. MORGANTI, F. MORSANI, N. NERI, E. PAOLONI, A. PROFETI, M. RAMA, G. RIZZO, J. WALSH, P. ELMER, O. LONG, A. PERAZZO, P. BURCHAT, A.J. EDWARDS, S. MAJEWSKI, B.A. PETERSEN, M. BONA, F. BIANCHI, D. GAMBA, P. TRAPANI, M. BOMBEN, L. BOSISIO, C. CARTARO, F. COSSUTTI, G. DELLA RICCA, S. DITTONGO, L. LANCERI, L. VITALE, M. DATTA, A. MIHALYI. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 569:1(2006), pp. 1-4.
none
Prodotti della ricerca::01 - Articolo su periodico
89
262
Article (author)
si
V. RE, M. BONDIOLI, M. BRUINSMA, S. CURRY, D. KIRKBY, J. BERRYHILL, S. BURKE, D. CALLAHAN, C. CAMPAGNARI, A. CUNHA, B. DAHMES, D. HALE, S. KYRE, J. RI...espandi
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/22606
Citazioni
ND
4
5
ND
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.