In this work we present a new compact and high-resolution Anger camera to be used in clinical and research environments where high overall spatial resolution and system compactness are required. The use of Silicon Drift Detectors (SDDs) as scintillator photodetectors, characterized by high quantum efficiency and low electronic noise, is the unique aspect of this camera. Two prototypes were developed during the project, with 5 × 5 SDDs and 10 × 10 SDDs (6 cm × 5 cm and 12 cm × 10 cm field-of-view, respectively). They provide a high intrinsic spatial resolution(< 1 mm), system spatial resolution of ∼ 2.67 mm @ 4 cm and appropriate sensitivity. The prototypes have been used for assessment of performance and first measurements in both clinical trials and small animal imaging. We report on the results of imaging measurements carried out in the laboratory with the prototypes and on the most significant results obtained so far with this new camera employed in several applications.

The HICAM Gamma Camera / C. Fiorini, P. Busca, R. Peloso, A. Abba, A. Geraci, C. Bianchi, G.L. Poli, G. Virotta, K. Erlandsson, B.F. Hutton, P. Lechner, H. Soltau, L. Struder, A. Pedretti, P. Van Mullekom, L. Ottobrini, G. Lucignani. - In: IEEE TRANSACTIONS ON NUCLEAR SCIENCE. - ISSN 0018-9499. - 59:3(2012), pp. 6196193.537-6196193.544.

The HICAM Gamma Camera

L. Ottobrini;G. Lucignani
2012

Abstract

In this work we present a new compact and high-resolution Anger camera to be used in clinical and research environments where high overall spatial resolution and system compactness are required. The use of Silicon Drift Detectors (SDDs) as scintillator photodetectors, characterized by high quantum efficiency and low electronic noise, is the unique aspect of this camera. Two prototypes were developed during the project, with 5 × 5 SDDs and 10 × 10 SDDs (6 cm × 5 cm and 12 cm × 10 cm field-of-view, respectively). They provide a high intrinsic spatial resolution(< 1 mm), system spatial resolution of ∼ 2.67 mm @ 4 cm and appropriate sensitivity. The prototypes have been used for assessment of performance and first measurements in both clinical trials and small animal imaging. We report on the results of imaging measurements carried out in the laboratory with the prototypes and on the most significant results obtained so far with this new camera employed in several applications.
Gamma camera; nuclear medicine; silicon drift detector
Settore MED/36 - Diagnostica per Immagini e Radioterapia
Settore MED/50 - Scienze Tecniche Mediche Applicate
2012
Article (author)
File in questo prodotto:
File Dimensione Formato  
The HICAM Gamma Camera.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 1.52 MB
Formato Adobe PDF
1.52 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/224746
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 16
social impact