Objective-To determine the incidence of adverse events within 24 hours after contrast-enhanced ultrasonography (CEUS) in dogs and cats and compare the risk of death within 24 hours after imaging for animals that underwent ultrasonography with and without injection of a contrast agent. Design-Retrospective case-control study. Animals-750 animals (411 case dogs, 238 control dogs, 77 case cats, and 24 control cats). Procedures At 11 institutions, medical records were reviewed of dogs and cats that had CEUS performed (cases) as were medical records of dogs and cats with clinical signs similar to those of case animals that had ultrasonography performed without injection of a contrast agent (controls). Information regarding signalment; preexisting disease; type, dose, and administration route of contrast agent used; immediate (within 1 hour after CEUS) and delayed (>1 and <= 24 hours after CEUS) adverse events; and occurrence and cause of death (when available) was extracted from each medical record. Risk of death within 24 hours after ultrasonography was compared between case and control animals. Results-Of the 411 case dogs, 3 had immediate adverse events (vomiting or syncope) and 1 had a delayed adverse event (vomiting). No adverse events were recorded for case cats. Twenty-three of 357 (6.4%) clinically ill case animals and 14 of 262 (5.3%) clinically ill control animals died within 24 hours after ultrasonography; risk of death did not differ between cases and controls. Conclusions and Clinical Relevance-Results indicated that CEUS was safe in dogs and cats.

Safety of contrast-enhanced ultrasonography in dogs and cats : 488 cases (2002-2011) / G.S. Seiler, J.C. Brown, J.A. Reetz, O. Taeymans, M. Bucknoff, F. Rossi, S. Ohlerth, D. Alder, N. Rademacher, W.T. Drost, R.E. Pollard, O. Travetti, P. Pey, J.H. Saunders, M.M. Shanaman, C.R. Oliveira, R.T. O'Brien, L. Gaschen. - In: JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION. - ISSN 0003-1488. - 242:9(2013 May 01), pp. 1255-1259.

Safety of contrast-enhanced ultrasonography in dogs and cats : 488 cases (2002-2011)

O. Travetti;
2013

Abstract

Objective-To determine the incidence of adverse events within 24 hours after contrast-enhanced ultrasonography (CEUS) in dogs and cats and compare the risk of death within 24 hours after imaging for animals that underwent ultrasonography with and without injection of a contrast agent. Design-Retrospective case-control study. Animals-750 animals (411 case dogs, 238 control dogs, 77 case cats, and 24 control cats). Procedures At 11 institutions, medical records were reviewed of dogs and cats that had CEUS performed (cases) as were medical records of dogs and cats with clinical signs similar to those of case animals that had ultrasonography performed without injection of a contrast agent (controls). Information regarding signalment; preexisting disease; type, dose, and administration route of contrast agent used; immediate (within 1 hour after CEUS) and delayed (>1 and <= 24 hours after CEUS) adverse events; and occurrence and cause of death (when available) was extracted from each medical record. Risk of death within 24 hours after ultrasonography was compared between case and control animals. Results-Of the 411 case dogs, 3 had immediate adverse events (vomiting or syncope) and 1 had a delayed adverse event (vomiting). No adverse events were recorded for case cats. Twenty-three of 357 (6.4%) clinically ill case animals and 14 of 262 (5.3%) clinically ill control animals died within 24 hours after ultrasonography; risk of death did not differ between cases and controls. Conclusions and Clinical Relevance-Results indicated that CEUS was safe in dogs and cats.
Settore VET/09 - Clinica Chirurgica Veterinaria
1-mag-2013
Article (author)
File in questo prodotto:
File Dimensione Formato  
JournAmericVeterMedAsso_Safety_2013.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 275.39 kB
Formato Adobe PDF
275.39 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/223477
Citazioni
  • ???jsp.display-item.citation.pmc??? 19
  • Scopus 48
  • ???jsp.display-item.citation.isi??? 43
social impact