Aim To verify the root canal treatment quality performed by dental school students with NiTi instrument in reciprocating motion. Methodology 18 patients were enrolled and 28 root canals were shaped and sealed by reciprocating NiTi Instruments (WaveOne – Maillefer – Baillegues – SUI) and pre-heated guttapercha (Thermafill-Maillefer – Baillegues – SUI). Radiographs were taken before, during and at the end of the endodontic treatment. Results Root fillings length was adequate in 26 of the 28 root canals evaluated (92,86%). 19 of them (73,08%) presented an extrusion of the endodontic sealer. No instrument breakage was reported. Conclusions In this very preliminar study, undergraduate students’ use of NiTi instruments in reciprocating motion might be a suitable alternative to traditional root canal therapy with low incidence of adverse effects.

Obiettivi Valutare la qualità dei trattamenti endodontici eseguiti da studenti del Corso di Laurea in Odontoiatria con strumenti in lega NiTi azionati con movimento reciprocante Materiali e metodi Diciotto soggetti con patologie endodontiche sono stati inclusi nello studio; un totale di 28 canali radicolari è stata preso in considerazione e strumentato con strumenti in lega NiTi (WaveOne - Maillefer - Baillegues - SUI) e sigillati con guttaperca pre-riscaldata (Thermafill-Maillefer - Baillegues - SUI). Risultati In 26 su 28 radici l’esame radiografico è risultato soddisfacente (92,86%). In 19 (73,08%) canali erano presenti estrusioni di cemento canalare. Non si sono verificate rotture. Conclusioni In questo studio preliminare, l’uso di strumenti azionati con movimento reciprocante da parte di studenti è possibile e potrebbe rappresentare una valida alternativa alle metodiche tradizionali.

Root canal treatment quality in undergraduate program: A preliminary report on NiTi reciprocating files / M. Silvani, E. Brambilla, A. Cerutti, M. Amato, M. Gagliani. - In: GIORNALE ITALIANO DI ENDODONZIA. - ISSN 1121-4171. - 27:1(2013), pp. 33-37. [10.1016/j.gien.2013.05.008]

Root canal treatment quality in undergraduate program: A preliminary report on NiTi reciprocating files

E. Brambilla
Secondo
;
M. Gagliani
Ultimo
2013

Abstract

Aim To verify the root canal treatment quality performed by dental school students with NiTi instrument in reciprocating motion. Methodology 18 patients were enrolled and 28 root canals were shaped and sealed by reciprocating NiTi Instruments (WaveOne – Maillefer – Baillegues – SUI) and pre-heated guttapercha (Thermafill-Maillefer – Baillegues – SUI). Radiographs were taken before, during and at the end of the endodontic treatment. Results Root fillings length was adequate in 26 of the 28 root canals evaluated (92,86%). 19 of them (73,08%) presented an extrusion of the endodontic sealer. No instrument breakage was reported. Conclusions In this very preliminar study, undergraduate students’ use of NiTi instruments in reciprocating motion might be a suitable alternative to traditional root canal therapy with low incidence of adverse effects.
Obiettivi Valutare la qualità dei trattamenti endodontici eseguiti da studenti del Corso di Laurea in Odontoiatria con strumenti in lega NiTi azionati con movimento reciprocante Materiali e metodi Diciotto soggetti con patologie endodontiche sono stati inclusi nello studio; un totale di 28 canali radicolari è stata preso in considerazione e strumentato con strumenti in lega NiTi (WaveOne - Maillefer - Baillegues - SUI) e sigillati con guttaperca pre-riscaldata (Thermafill-Maillefer - Baillegues - SUI). Risultati In 26 su 28 radici l’esame radiografico è risultato soddisfacente (92,86%). In 19 (73,08%) canali erano presenti estrusioni di cemento canalare. Non si sono verificate rotture. Conclusioni In questo studio preliminare, l’uso di strumenti azionati con movimento reciprocante da parte di studenti è possibile e potrebbe rappresentare una valida alternativa alle metodiche tradizionali.
Obturation technique; Reciprocating files; Root canal treatment; Treatment quality; Undergraduate teaching
Settore MED/28 - Malattie Odontostomatologiche
2013
Article (author)
File in questo prodotto:
File Dimensione Formato  
PIIS1121417113000095.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 613.91 kB
Formato Adobe PDF
613.91 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/223275
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 10
  • ???jsp.display-item.citation.isi??? ND
  • OpenAlex ND
social impact