Aims and background. The purpose of the study was to develop a general method able to quantify the mutual disposition in the 3D space of critical organs with respect to the target when these structures are designed for a radiotherapy treatment plan. To that end, We introduce the "expansion intersection histogram", a function defined as the intersection between an organ at risk and the target volume, while the target is expanded in 3D. Methods and study design. A software was developed to calculate the expansion intersection histogram of anatomical structures exported in a DICOM format from a commercial treatment planning system. A virtual phantom with spherical and cylindrical objects arranged in different dispositions in the 3D space was created for testing the software under known conditions. Results and conclusions. Expansion intersection histogram computation was tested against reference data derived analytically for spherical volumes, with a resulting maximum error of 0.5%. Specific geometric features derived from the expansion intersection histogram, such as the distance between a selected target and each different ideal volume included in the virtual phantom, well matched the corresponding theoretical expected values. The expansion intersection histogram was evaluated also for the anatomical structures of a real patient. Data show this method as a tool to effectively take into account the mutual disposition of each critical organ with respect to the target, summarized in characteristics of distance, shape and orientation. The expansion intersection histogram method integrates and extends other preexisting modalities for evaluating the geometrical relationships among radiotherapy volumes and could be used to improve planning optimization.

Geometry of volumes in radiotherapy planning. A new method for a quantitative assessment / S. Tomatis, M. Carrara, E. Massafra, G. Naldi, M. Palazzi, E. Orlandi, R. Marchesini. - In: TUMORI. - ISSN 0300-8916. - 97:4(2011), pp. 503-509.

Geometry of volumes in radiotherapy planning. A new method for a quantitative assessment

G. Naldi;
2011

Abstract

Aims and background. The purpose of the study was to develop a general method able to quantify the mutual disposition in the 3D space of critical organs with respect to the target when these structures are designed for a radiotherapy treatment plan. To that end, We introduce the "expansion intersection histogram", a function defined as the intersection between an organ at risk and the target volume, while the target is expanded in 3D. Methods and study design. A software was developed to calculate the expansion intersection histogram of anatomical structures exported in a DICOM format from a commercial treatment planning system. A virtual phantom with spherical and cylindrical objects arranged in different dispositions in the 3D space was created for testing the software under known conditions. Results and conclusions. Expansion intersection histogram computation was tested against reference data derived analytically for spherical volumes, with a resulting maximum error of 0.5%. Specific geometric features derived from the expansion intersection histogram, such as the distance between a selected target and each different ideal volume included in the virtual phantom, well matched the corresponding theoretical expected values. The expansion intersection histogram was evaluated also for the anatomical structures of a real patient. Data show this method as a tool to effectively take into account the mutual disposition of each critical organ with respect to the target, summarized in characteristics of distance, shape and orientation. The expansion intersection histogram method integrates and extends other preexisting modalities for evaluating the geometrical relationships among radiotherapy volumes and could be used to improve planning optimization.
Geometrical features; Quantification; Radiotherapy volumes; Treatment plan optimization
Settore FIS/07 - Fisica Applicata(Beni Culturali, Ambientali, Biol.e Medicin)
Settore MAT/08 - Analisi Numerica
2011
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/222183
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact