The spontaneous low- and high-frequency rhythms in the sympathetic discharge of decerebrate artificially ventilated cats are affected by external ventilation. Two graphical methods (i.e. the space-time separation plot and the frequency tracking locus) are used to classify the non-linear interactions. The observed behaviours in the sympathetic discharge consist of phase-locked periodic dynamics (at various frequency ratios with ventilation), quasiperiodic and aperiodic patterns. They depend on the experimental condition. In control condition the sympathetic discharge appears more frequently locked to each ventilatory cycle (1:1 dynamics). However, some cases of quasiperiodic dynamics are found. A sympathetic activation stimulus, such as inferior vena cava occlusion, is able to synchronise slow rhythms in the sympathetic discharge to a subharmonic of ventilation. During a sympathetic inhibition stimulus, such as aortic constriction, 1:1 dynamics is detected but the amplitude of the sympathetic responses can be modulated by unlocked slow rhythms. Moreover, some cases of aperiodic dynamics are observed. Vagotomy reduces the 1:1 coupling between sympathetic outflow and ventilation. Vagotomy plus spinalisation disrupts periodic dynamics in the sympathetic discharge so that irregular and complex patterns are found.

Classification of coupling patterns among spontaneous rhythms and ventilation in the sympathetic discharge of decerebrate cats / A. Porta, G. Baselli, N. Montano, T. Gnecchi-Ruscone, F. Lombardi, A. Malliani, S. Cerutti. - In: BIOLOGICAL CYBERNETICS. - ISSN 0340-1200. - 75:2(1996 Aug), pp. 163-172.

Classification of coupling patterns among spontaneous rhythms and ventilation in the sympathetic discharge of decerebrate cats

A. Porta
Primo
;
N. Montano;F. Lombardi;A. Malliani
Penultimo
;
1996

Abstract

The spontaneous low- and high-frequency rhythms in the sympathetic discharge of decerebrate artificially ventilated cats are affected by external ventilation. Two graphical methods (i.e. the space-time separation plot and the frequency tracking locus) are used to classify the non-linear interactions. The observed behaviours in the sympathetic discharge consist of phase-locked periodic dynamics (at various frequency ratios with ventilation), quasiperiodic and aperiodic patterns. They depend on the experimental condition. In control condition the sympathetic discharge appears more frequently locked to each ventilatory cycle (1:1 dynamics). However, some cases of quasiperiodic dynamics are found. A sympathetic activation stimulus, such as inferior vena cava occlusion, is able to synchronise slow rhythms in the sympathetic discharge to a subharmonic of ventilation. During a sympathetic inhibition stimulus, such as aortic constriction, 1:1 dynamics is detected but the amplitude of the sympathetic responses can be modulated by unlocked slow rhythms. Moreover, some cases of aperiodic dynamics are observed. Vagotomy reduces the 1:1 coupling between sympathetic outflow and ventilation. Vagotomy plus spinalisation disrupts periodic dynamics in the sympathetic discharge so that irregular and complex patterns are found.
Settore ING-INF/06 - Bioingegneria Elettronica e Informatica
Settore MED/09 - Medicina Interna
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
ago-1996
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/22074
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 26
  • ???jsp.display-item.citation.isi??? ND
social impact