AIMS: To explore the potentiality of cardiovascular magnetic resonance (CMR) in the quantitative evaluation of mitral valve annulus (MVA) and tricuspid valve annulus (TVA) morphology and dynamics. METHODS AND RESULTS: CMR was performed in 13 normal subjects and 9 patients with mitral (n = 7) or tricuspid regurgitation (n = 2), acquiring cine-images in 18 radial long-axis planes passing through the middle of MVA or TVA. A novel algorithm was used to obtain dynamic three-dimensional (3D) reconstruction of MVA and TVA. Analysis was feasible in all cases, allowing accurate 3D annular reconstruction and tracking. The 3D area increased from systole [MVA, median = 10.0 cm(2) (first quartile = 8.6, third quartile = 11.4); TVA, 11.2 cm(2) (8.8-13.2)] to diastole [MVA, 10.6 cm(2) (9.4, 11.7); TVA, 11.9 cm(2) (9.2-13.5)], with TVA larger than MVA. While the longest diameter showed similar systolic and diastolic values, the shortest diameter elongated from systole [MVA, 30 mm (29-33); TVA, 33 mm (31-36)] to diastole [MVA, 31 mm (29-32); TVA, 36 mm (33-39)]. Also, TVA became more circular than MVA. TVA showed lower peak systolic excursion in the septal [15.9 mm (13.0-18.5)] and anterior regions [17.9 mm (12.2-20.7)] compared with the posterior [21.9 mm (18.6-24.0)] segment. Values in MVA were smaller than in TVA, slightly higher in anterior [11.2 mm (9.5-13.0)] than in posterior [12.4 mm (10.2-14.6)] segments. Valvular regurgitation was associated with enlarged, flattened, and more circular annuli. CONCLUSION: The applied method was feasible and accurate in normal and regurgitant valves, and may potentially have an impact on diagnosis, improvement of surgical techniques and design of annular prostheses.

Three-dimensional dynamic assessment of tricuspid and mitral annuli using cardiovascular magnetic resonance / F. Maffessanti, P. Gripari, G. Pontone, D. Andreini, E. Bertella, S. Mushtaq, G. Tamborini, L. Fusini, M. Pepi, E.G. Caiani. - In: EUROPEAN HEART JOURNAL. CARDIOVASCULAR IMAGING. - ISSN 2047-2412. - 14:10(2013 Oct), pp. 986-995. [10.1093/ehjci/jet004]

Three-dimensional dynamic assessment of tricuspid and mitral annuli using cardiovascular magnetic resonance

P. Gripari;G. Pontone;D. Andreini;E. Bertella;S. Mushtaq;L. Fusini;
2013

Abstract

AIMS: To explore the potentiality of cardiovascular magnetic resonance (CMR) in the quantitative evaluation of mitral valve annulus (MVA) and tricuspid valve annulus (TVA) morphology and dynamics. METHODS AND RESULTS: CMR was performed in 13 normal subjects and 9 patients with mitral (n = 7) or tricuspid regurgitation (n = 2), acquiring cine-images in 18 radial long-axis planes passing through the middle of MVA or TVA. A novel algorithm was used to obtain dynamic three-dimensional (3D) reconstruction of MVA and TVA. Analysis was feasible in all cases, allowing accurate 3D annular reconstruction and tracking. The 3D area increased from systole [MVA, median = 10.0 cm(2) (first quartile = 8.6, third quartile = 11.4); TVA, 11.2 cm(2) (8.8-13.2)] to diastole [MVA, 10.6 cm(2) (9.4, 11.7); TVA, 11.9 cm(2) (9.2-13.5)], with TVA larger than MVA. While the longest diameter showed similar systolic and diastolic values, the shortest diameter elongated from systole [MVA, 30 mm (29-33); TVA, 33 mm (31-36)] to diastole [MVA, 31 mm (29-32); TVA, 36 mm (33-39)]. Also, TVA became more circular than MVA. TVA showed lower peak systolic excursion in the septal [15.9 mm (13.0-18.5)] and anterior regions [17.9 mm (12.2-20.7)] compared with the posterior [21.9 mm (18.6-24.0)] segment. Values in MVA were smaller than in TVA, slightly higher in anterior [11.2 mm (9.5-13.0)] than in posterior [12.4 mm (10.2-14.6)] segments. Valvular regurgitation was associated with enlarged, flattened, and more circular annuli. CONCLUSION: The applied method was feasible and accurate in normal and regurgitant valves, and may potentially have an impact on diagnosis, improvement of surgical techniques and design of annular prostheses.
No
English
annular geometry ; cardiovascular magnetic resonance ; mitral valve annulus ; tricuspid valve annulus
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
Articolo
Esperti anonimi
Pubblicazione scientifica
ott-2013
Oxford University Press
14
10
986
995
10
Pubblicato
Periodico con rilevanza internazionale
Pubmed
info:eu-repo/semantics/article
Three-dimensional dynamic assessment of tricuspid and mitral annuli using cardiovascular magnetic resonance / F. Maffessanti, P. Gripari, G. Pontone, D. Andreini, E. Bertella, S. Mushtaq, G. Tamborini, L. Fusini, M. Pepi, E.G. Caiani. - In: EUROPEAN HEART JOURNAL. CARDIOVASCULAR IMAGING. - ISSN 2047-2412. - 14:10(2013 Oct), pp. 986-995. [10.1093/ehjci/jet004]
none
Prodotti della ricerca::01 - Articolo su periodico
10
262
Article (author)
no
F. Maffessanti, P. Gripari, G. Pontone, D. Andreini, E. Bertella, S. Mushtaq, G. Tamborini, L. Fusini, M. Pepi, E.G. Caiani
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/220681
Citazioni
  • ???jsp.display-item.citation.pmc??? 16
  • Scopus 72
  • ???jsp.display-item.citation.isi??? 62
social impact