The Amplitude of Dominant T-Wave Alternans (ADTWA) is a recently introduced index which quantifies the presence of microvolt T Wave Alternans (TWA) on surface ECG recordings. In this paper we investigate the reliability of ADTWA and its robustness against broadband noise. At this regard, we generated synthetic 12-leads ECG recordings through a forward electrophysiological model and we added TWA, at different extent, by modulating the variation of the repolarization times of transmembrane action potentials across even and odd beats. Using a stochastic model, we derived an analytical relationship between the repolarization variation injected into the model and TWA at the surface, thus offering a strategy to evaluate lead sensitivity. In terms of robustness, the results of the simulations show that ADTWA correctly measured the amplitude of synthetic TWA with an average error of 3.3% ± 5.8% in absence of noise. When a 100 μV peak-to-peak broadband noise is present, its effects on estimation errors were kept limited by singular value decomposition on which ADTWA builds.
Amplitude of dominant T-wave alternans assessment on ECGs obtained from a biophysical model / R. Sassi, L.T. Mainardi, S. Cerutti (PROCEEDINGS OF THE ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY). - In: Engineering in Medicine and Biology Society,EMBC, 2011 Annual International Conference of the IEEE[s.l] : IEEE Press, 2011. - ISBN 978-1-4244-4121-1. - pp. 5872-5875 (( Intervento presentato al 33. convegno Annual International Conference of the IEEE, Engineering in Medicine and Biology Society (EMBC) tenutosi a Boston nel 2011 [10.1109/IEMBS.2011.6091452].
Amplitude of dominant T-wave alternans assessment on ECGs obtained from a biophysical model
R. Sassi;
2011
Abstract
The Amplitude of Dominant T-Wave Alternans (ADTWA) is a recently introduced index which quantifies the presence of microvolt T Wave Alternans (TWA) on surface ECG recordings. In this paper we investigate the reliability of ADTWA and its robustness against broadband noise. At this regard, we generated synthetic 12-leads ECG recordings through a forward electrophysiological model and we added TWA, at different extent, by modulating the variation of the repolarization times of transmembrane action potentials across even and odd beats. Using a stochastic model, we derived an analytical relationship between the repolarization variation injected into the model and TWA at the surface, thus offering a strategy to evaluate lead sensitivity. In terms of robustness, the results of the simulations show that ADTWA correctly measured the amplitude of synthetic TWA with an average error of 3.3% ± 5.8% in absence of noise. When a 100 μV peak-to-peak broadband noise is present, its effects on estimation errors were kept limited by singular value decomposition on which ADTWA builds.File | Dimensione | Formato | |
---|---|---|---|
06091452.pdf
accesso riservato
Tipologia:
Publisher's version/PDF
Dimensione
1.41 MB
Formato
Adobe PDF
|
1.41 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.