The Amplitude of Dominant T-Wave Alternans (ADTWA) is a recently introduced index which quantifies the presence of microvolt T Wave Alternans (TWA) on surface ECG recordings. In this paper we investigate the reliability of ADTWA and its robustness against broadband noise. At this regard, we generated synthetic 12-leads ECG recordings through a forward electrophysiological model and we added TWA, at different extent, by modulating the variation of the repolarization times of transmembrane action potentials across even and odd beats. Using a stochastic model, we derived an analytical relationship between the repolarization variation injected into the model and TWA at the surface, thus offering a strategy to evaluate lead sensitivity. In terms of robustness, the results of the simulations show that ADTWA correctly measured the amplitude of synthetic TWA with an average error of 3.3% ± 5.8% in absence of noise. When a 100 μV peak-to-peak broadband noise is present, its effects on estimation errors were kept limited by singular value decomposition on which ADTWA builds.

Amplitude of dominant T-wave alternans assessment on ECGs obtained from a biophysical model / R. Sassi, L.T. Mainardi, S. Cerutti (PROCEEDINGS OF THE ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY). - In: Engineering in Medicine and Biology Society,EMBC, 2011 Annual International Conference of the IEEE[s.l] : IEEE Press, 2011. - ISBN 978-1-4244-4121-1. - pp. 5872-5875 (( Intervento presentato al 33. convegno Annual International Conference of the IEEE, Engineering in Medicine and Biology Society (EMBC) tenutosi a Boston nel 2011 [10.1109/IEMBS.2011.6091452].

Amplitude of dominant T-wave alternans assessment on ECGs obtained from a biophysical model

R. Sassi;
2011

Abstract

The Amplitude of Dominant T-Wave Alternans (ADTWA) is a recently introduced index which quantifies the presence of microvolt T Wave Alternans (TWA) on surface ECG recordings. In this paper we investigate the reliability of ADTWA and its robustness against broadband noise. At this regard, we generated synthetic 12-leads ECG recordings through a forward electrophysiological model and we added TWA, at different extent, by modulating the variation of the repolarization times of transmembrane action potentials across even and odd beats. Using a stochastic model, we derived an analytical relationship between the repolarization variation injected into the model and TWA at the surface, thus offering a strategy to evaluate lead sensitivity. In terms of robustness, the results of the simulations show that ADTWA correctly measured the amplitude of synthetic TWA with an average error of 3.3% ± 5.8% in absence of noise. When a 100 μV peak-to-peak broadband noise is present, its effects on estimation errors were kept limited by singular value decomposition on which ADTWA builds.
Approximation methods; Electric potential; Electrocardiography; Equations; Lead; Mathematical model; Noise
Settore ING-INF/06 - Bioingegneria Elettronica e Informatica
Settore INF/01 - Informatica
2011
Institute of Electrical and Electronics Engineers
Book Part (author)
File in questo prodotto:
File Dimensione Formato  
06091452.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 1.41 MB
Formato Adobe PDF
1.41 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/217502
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 6
social impact