Optical sources that deterministically produce single photons with a high suppression of multi-photon emission and a negligible background component are promising candidates for standard sources for quantum metrology, quantum communication and foundations of quantum mechanics. In this paper, the photon number distribution of non-classical light emitted by nitrogen vacancy (NV) centres in nano-diamonds is studied by three different experimental techniques. The photon number resolving transition edge sensor (TES) detector and the On/Off detection method are applied to determine the diagonal elements of the optical density matrix. From the data measured by the two methods the second order correlation function at time delay zero is calculated and compared with the g2(0)-values obtained by Hanbury Brown–Twiss (HBT) interferometric measurements. Among the g2(0)-values evaluated with the three techniques, we found good agreement in the results for a single photon emitter with a g2(0)-value close to zero and a multi-photon source with a g2(0)-value of approximately 0.5.

Photon number statistics of NV centre emission / W. Schmunk, M. Gramegna, G. Brida, I. P. Degiovanni, M. Genovese, H. Hofer, S. Kück, L. Lolli, M. G. A. Paris, S. Peters, M. Rajteri, A. M. Racu, A. Ruschhaupt, E. Taralli, P. Traina. - In: METROLOGIA. - ISSN 0026-1394. - 49:2(2012), pp. S156-S160. [10.1088/0026-1394/49/2/S156]

Photon number statistics of NV centre emission

M.G.A. Paris;
2012

Abstract

Optical sources that deterministically produce single photons with a high suppression of multi-photon emission and a negligible background component are promising candidates for standard sources for quantum metrology, quantum communication and foundations of quantum mechanics. In this paper, the photon number distribution of non-classical light emitted by nitrogen vacancy (NV) centres in nano-diamonds is studied by three different experimental techniques. The photon number resolving transition edge sensor (TES) detector and the On/Off detection method are applied to determine the diagonal elements of the optical density matrix. From the data measured by the two methods the second order correlation function at time delay zero is calculated and compared with the g2(0)-values obtained by Hanbury Brown–Twiss (HBT) interferometric measurements. Among the g2(0)-values evaluated with the three techniques, we found good agreement in the results for a single photon emitter with a g2(0)-value close to zero and a multi-photon source with a g2(0)-value of approximately 0.5.
Settore FIS/03 - Fisica della Materia
2012
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/217285
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 14
social impact