Between January 1990 and September 1992, ten patients required assisted circulation for postcardiotomy heart failure which was unresponsive to inotropic drugs and aortic counterpulsation. All patients were supported by a Bio-Medicus centrifugal pump (biventricular assist in five, left ventricular in three, right ventricular in two); six had ischaemic heart disease, two a congenital ventricular septal defect, one an acute mitral valve incompetence and one an aortic type 'A' dissection. The mean duration of circulatory support was 5.1 days (range 2 hours to 8 days). Six patients were weaned from the device and four were discharged; the perioperative deaths among the patients weaned from support were the result of cerebral haemorrhage and multiorgan failure respectively. No late deaths occurred at a mean follow-up of 15 months. Common complications were bleeding (40%), acute renal failure (30%) and sepsis (30%). All patients who developed renal failure died. The high incidence of haemorrhagic complications makes the use of pre-heparinized circuits desirable as these patients do not then require additional anticoagulation.
Assisted circulation in postcardiotomy heart failure: experience with the Bio-Medicus centrifugal pump in ten patients / G. Paolini, M. Triggiani, G. Di Credico, M. Pocar, P. Stefano, E. Montorsi, F. Simeone, G. Paolillo, A. Grossi. - In: CARDIOVASCULAR SURGERY. - ISSN 0967-2109. - 2:5(1994 Oct), pp. 630-633. [10.1177/096721099400200518]
Assisted circulation in postcardiotomy heart failure: experience with the Bio-Medicus centrifugal pump in ten patients
G. Di Credico;M. Pocar;A. GrossiUltimo
1994
Abstract
Between January 1990 and September 1992, ten patients required assisted circulation for postcardiotomy heart failure which was unresponsive to inotropic drugs and aortic counterpulsation. All patients were supported by a Bio-Medicus centrifugal pump (biventricular assist in five, left ventricular in three, right ventricular in two); six had ischaemic heart disease, two a congenital ventricular septal defect, one an acute mitral valve incompetence and one an aortic type 'A' dissection. The mean duration of circulatory support was 5.1 days (range 2 hours to 8 days). Six patients were weaned from the device and four were discharged; the perioperative deaths among the patients weaned from support were the result of cerebral haemorrhage and multiorgan failure respectively. No late deaths occurred at a mean follow-up of 15 months. Common complications were bleeding (40%), acute renal failure (30%) and sepsis (30%). All patients who developed renal failure died. The high incidence of haemorrhagic complications makes the use of pre-heparinized circuits desirable as these patients do not then require additional anticoagulation.File | Dimensione | Formato | |
---|---|---|---|
1994 CVS VAD.pdf
accesso riservato
Tipologia:
Publisher's version/PDF
Dimensione
2.27 MB
Formato
Adobe PDF
|
2.27 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.