OBJECTIVES: The level of pressure-support ventilation can affect mean airway pressure and potentially lung volume, but its increase is usually associated with a reduced respiratory rate, and the net effects on the gas exchange process and its components, including end-expiratory lung volume, have not been carefully studied. We measured pulmonary conductance for gas exchange based on lung diffusion for carbon monoxide in patients receiving pressure-support ventilation. DESIGN: Prospective, randomized, crossover study. SETTING: Medical intensive care unit of a university hospital. PATIENTS: Sixteen patients mechanically ventilated in pressure-support ventilation mode and free from chronic obstructive pulmonary disease. INTERVENTIONS: Two pressure-support ventilation levels (5 cm H2O difference) at the same level of positive end-expiratory pressure. MEASUREMENTS AND MAIN RESULTS: End-expiratory lung volume, lung diffusion for carbon monoxide, and SpO2/Fio2 were evaluated. Increasing pressure-support ventilation by 5 cm H2O significantly increased the mean tidal volume from 6.8 to 8.5 mL/kg of predicted body weight and decreased the mean respiratory rate by 6.6 breaths per minute. Although SpO2/Fio2 did not change significantly, there was a slight but significant decrease in lung diffusion for carbon monoxide (average decay rate of 4.5%) at high pressure-support ventilation. The pressure-support ventilation level did not significantly affect end-expiratory lung volume (1737±629 mL at 9.6±2.5 cm H2O pressure-support ventilation level vs. 1749±657 mL at 14.9±2.1 cm H2O pressure-support ventilation level). CONCLUSIONS: A 5-cm H2O increase in pressure-support ventilation neither affected end-expiratory lung volume nor increased the pulmonary volume participating in gas exchange. A target tidal volume closer to 6 mL/kg of predicted body weight than to 8 mL/kg during pressure-support ventilation was associated with better gas exchange.
Effect of pressure support on end-expiratory lung volume and lung diffusion for carbon monoxide / N. Pinto Da Costa, F. Di Marco, A. Lyazidi, G. Carteaux, M. Sarni, L. Brochard. - In: CRITICAL CARE MEDICINE. - ISSN 0090-3493. - 39:10(2011 Oct), pp. 2283-2289.
Effect of pressure support on end-expiratory lung volume and lung diffusion for carbon monoxide
F. Di MarcoSecondo
;
2011
Abstract
OBJECTIVES: The level of pressure-support ventilation can affect mean airway pressure and potentially lung volume, but its increase is usually associated with a reduced respiratory rate, and the net effects on the gas exchange process and its components, including end-expiratory lung volume, have not been carefully studied. We measured pulmonary conductance for gas exchange based on lung diffusion for carbon monoxide in patients receiving pressure-support ventilation. DESIGN: Prospective, randomized, crossover study. SETTING: Medical intensive care unit of a university hospital. PATIENTS: Sixteen patients mechanically ventilated in pressure-support ventilation mode and free from chronic obstructive pulmonary disease. INTERVENTIONS: Two pressure-support ventilation levels (5 cm H2O difference) at the same level of positive end-expiratory pressure. MEASUREMENTS AND MAIN RESULTS: End-expiratory lung volume, lung diffusion for carbon monoxide, and SpO2/Fio2 were evaluated. Increasing pressure-support ventilation by 5 cm H2O significantly increased the mean tidal volume from 6.8 to 8.5 mL/kg of predicted body weight and decreased the mean respiratory rate by 6.6 breaths per minute. Although SpO2/Fio2 did not change significantly, there was a slight but significant decrease in lung diffusion for carbon monoxide (average decay rate of 4.5%) at high pressure-support ventilation. The pressure-support ventilation level did not significantly affect end-expiratory lung volume (1737±629 mL at 9.6±2.5 cm H2O pressure-support ventilation level vs. 1749±657 mL at 14.9±2.1 cm H2O pressure-support ventilation level). CONCLUSIONS: A 5-cm H2O increase in pressure-support ventilation neither affected end-expiratory lung volume nor increased the pulmonary volume participating in gas exchange. A target tidal volume closer to 6 mL/kg of predicted body weight than to 8 mL/kg during pressure-support ventilation was associated with better gas exchange.Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.